OBJECTIVE To compare the accuracy of standard supplementary views and GE digital breast tomosynthesis (DBT) for assessment of soft-tissue mammographic abnormalities. METHODS Women recalled for further assessment of soft-tissue abnormalities were recruited and received standard supplementary views (typically spot compression views) and two-view GE DBT. The added value of DBT in the assessment process was determined by analysing data collected prospectively by radiologists working up the cases. Following anonymization of cases, there was also a retrospective multireader review. The readers first read bilateral standard two-view digital mammography (DM) together with the supplementary mammographic views and gave a combined score for suspicion of malignancy on a five-point scale. The same readers then read bilateral standard two-view DM together with two-view DBT. Pathology data were obtained. Differences were assessed using receiver operating characteristic analysis. RESULTS The study population was 342 lesions in 322 patients. The final diagnosis was malignant in 113 cases (33%) and benign/normal in 229 cases (67%). In the prospective analysis, the performance of two-view DM plus DBT was at least equivalent to the performance of two-view DM and standard mammographic supplementary views-the area under the curve (AUC) was 0.946 and 0.922, respectively, which did not reach statistical significance. Similar results were obtained for the retrospective review-AUC was 0.900 (DBT) and 0.873 (supplementary views), which did not reach statistical significance. CONCLUSION The accuracy of GE DBT in the assessment of screen detected soft-tissue abnormalities is equivalent to the use of standard supplementary mammographic views. ADVANCES IN KNOWLEDGE The vast majority of evidence relating to the use of DBT has been gathered from research using Hologic equipment. This study provides evidence for the use of the commercially available GE DBT system demonstrating that it is at least equivalent to supplementary mammographic views in the assessment of soft-tissue screen-detected abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis.

AIM To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. MATERIALS AND METHODS Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammog...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Digital Breast Tomosynthesis - 06/13

Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...

متن کامل

MM.05.012 Digital Breast Tomosynthesis - 8/14

Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...

متن کامل

Screening-detected desmoid tumor of the breast: findings at conventional imaging and digital breast tomosynthesis

Desmoid tumor of the breast is a rare benign entity that usually is mistaken for carcinoma clinically and radiologically. We report two cases of desmoid tumor of the breast detected by mammography screening using digital breast tomosynthesis (DBT). The larger tumor was detected at both full-field digital mammography (FFDM) and DBT. The smaller desmoid tumor, however, was identified only at tomo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 89 1058  شماره 

صفحات  -

تاریخ انتشار 2016