Effect of simulated early weight bearing on micromotion and pullout strength of uncemented distal femoral stems.
نویسندگان
چکیده
The effect of simulated early weight bearing on both micromotion and pullout strength of uncemented distal femoral stems was evaluated in this study. The effect of stem endosteal contact and bone quality on implant pullout strength was also analyzed. A randomized matched-pair study was performed using 8 bilateral pairs of fresh human cadaveric femoral specimens. Each specimen pair was dual-energy x-ray absorptiometry scanned, uniformly implanted, fluoroscopically imaged, and randomly assigned to the cycled or uncycled group. The cycled group received 5000 cycles of axial compressive loading (to 700 N) and the contralateral side was not cycled. Micromotion was monitored during cycling and compared with a failure threshold (150 µm), and all implants underwent direct axial distraction (pullout) testing. During cycling, minimal micromotion was observed with an asymptotic decrease in differential motion between the first and last 50 cycles. Both cycled and uncycled groups demonstrated no statistical difference in average pullout force (4888±2124 N vs 4367±1154 N; P=.43). The percentage of cortical contact for each implant was determined from panoramic fluoroscopy images using digital image analysis software. Contact area for the distal third of the stem showed the highest correlation with pullout force and with predicting pullout force. Bone quality did not correlate with pullout force (r(2)=0.367) or stem contact area (r(2)=0.394). In sum, press-fit uncemented femoral stems did not loosen or demonstrate decreased pullout strength with early weight bearing simulated by cyclical axial compressive loading.
منابع مشابه
Experimental and FDM study on the effect of geogrid tensile strength on pullout resistance
This paper presents the effect of geogrid tensile strength by calculating pullout resistance and geogrid-soil interaction mechanism. In order to investigate this interface, a series of pullout tests have been conducted by large scale reformed direct shear test apparatus in both cohesive and granular soils. In numerical, finite difference software FLAC3D has been carried out on experimental test...
متن کاملAn Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
Surgical treatment to restore full range of motion and full weight bearing after extensive femoral bone resection in patients with primary or metastatic femoral tumours is individually challenging. Especially when the remaining distal or proximal bone is very short, a rigid fixation of an implant is difficult to achieve due to the reverse funnel shape of the metaphysis. Herein, we present a nov...
متن کاملDynamic plate osteosynthesis for fracture stabilization: how to do it
Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent...
متن کاملPartial versus early full weight bearing after uncemented total hip arthroplasty: a meta-analysis
BACKGROUND This meta-analysis aimed to investigate the efficacy and safety of partial weight bearing (PWB) versus early full weight bearing (FWB) after uncemented total hip arthroplasty (THA). METHODS We conducted a search in PubMed, EMBASE, The Cochrane Library, and Web of Science for randomized controlled trials (RCTs) and non-RCTs comparing PWB and early FWB after uncemented THA. Two autho...
متن کاملThe Effect of Physiological Load Configuration on Interface Micromotion in Cementless Femoral Stems
The most commonly reported failure modes of cementless hip stems are loosening and thigh pain; both are attributed to the relative motion at the bone-implant interface due to failure to achieve sufficient primary fixation. Accurate predictions of hip stems’ stability are therefore crucial to the pre-clinical analyses of hip arthroplasty. This study uses finite element technique to analyse the e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2015