Analysis and fractionation of silicone and fluorosilicone oils for intraocular use.
نویسندگان
چکیده
Silicone oil (SiO) and fluorosilicone oil (FSiO) are useful in difficult cases of retinal detachment surgery. Unidentified low-molecular-weight components (LMWC) and residual catalysts in SiO and FSiO have been implicated in the adverse reactions of the oils in the eye. The authors analyzed LMWC of SiO and FSiO using a gas chromatograph (GC) equipped with a 6-ft x 2-mm column packed with 3% SP-2250 and a flame-ionization detector. By commercially available standards and a homologous series plot, MD3M to MD23M (linear LMWC) and D4 to D30 (cyclic LMWC) were positively identified in commercial-grade 1000-centistokes (cs) SiO. Commercial-grade 12,500-cs SiO contained GC-detectable LMWC (up to MD28M and D30) at higher concentrations than commercial-grade 1000 cs SiO, although the weight percent of acetone-extractable LMWC (including those larger than MD28M and D30) was less in the former than in the latter. The GC-detectable LMWC in most medical-grade SiO were less than those in commercial-grade SiO. Tetramethylammonium siloxanolate (a residual catalyst) and tributylphosphine oxide (a heat-decomposition product of a polymerization catalyst) were tentatively identified in commercial- and medical-grade 12,500-cs SiO, respectively. Commercial-grade 1000- and 10,000-cs FSiO also contained LMWC, including F3 and/or F4 (cyclic LMWC). To eliminate LMWC from the oils, the authors developed a solvent fractionation method using acetone for SiO and hexane for FSiO. After continuous solvent extraction of SiO for 2 weeks and FSiO for 3 weeks, all measurable LMWC were eliminated from the oils.
منابع مشابه
Emulsification tendency of silicone-phenylsilicone copolymer.
PURPOSE We compared the emulsification tendency of silicone-phenylsilicone copolymer (DPC; 5%-phenylated, specific gravity 0.984) with that of silicone oil (SO; specific gravity 0.966) and fluorosilicone oil (FSO; specific gravity 1.256), all of which are used clinically as intraocular tamponades. METHODS We investigated the tendencies of emulsification in SO, FSO, and DPC. Each was placed in...
متن کاملFluorosilicone oil in the treatment of retinal detachment.
We evaluated the use of a heavier-than-water fluorinated silicone oil in the treatment of 30 selected cases of complicated retinal detachment from January 1988 to July 1989. Proliferative vitreoretinopathy grade C-2 or greater accounted for 19 cases, proliferative diabetic retinopathy with traction detachment for two cases, giant retinal tears five, ruptured globe with retinal detachment two, m...
متن کاملSilicone oil egressing through an inferiorly implanted ahmed valve.
Silicone oil use as an adjunct to complicated vitreoretinal surgery is becoming more frequent. Refractory glaucoma in these patients is common. Isolated reports have mentioned the possibility of silicone oil migrating and/or obstructing the tube in the anterior chamber of Molteno implants (IOP, Costa Mesa, Calif). This report describes a case of intraocular silicone oil egressing through an Ahm...
متن کاملRefractive Change Caused Silicone Oil Adhesion to the Intraocular Lens Following Nd:YAG Posterior Capsulotomy
A 32-year-old female who had undergone the silicone oil removal procedure presented with visual disturbance in her left eye. Several months previous, she had cataract surgery in a private clinic, and a month later she had a Nd:YAG laser procedure for posterior capsulotomy. The slit-lamp examination revealed silicone oil droplets that had adhered to the intraocular lens where the posterior capsu...
متن کامل1126 Silicone/fluorosilicone copolymer oil (SIFO) in vitreoretinal surgery
m: Silicone/fluomsilicone copolymer oii (SiFO) is a polysiloxane derivative potentially us&d as mtraoperative tool and long term retinal tatnponade agent. SiFO is characterized by higher-than-water density and low viscosity; its intraocular tolerance in rabbits up to two months is siroilra to that of silicone oil. &j&t&. SiFO was used in 9 eyes with complicated retinal detachment. Five patients...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 31 10 شماره
صفحات -
تاریخ انتشار 1990