Use and modifications of cervical and upper thoracic laminar screws in posterior stabilization.
نویسندگان
چکیده
AIM Laminar screw technique is used to stabilize C2 and other levels when other techniques cannot be performed. MATERIAL AND METHODS The patients underwent laminar screws at cervical and upper thoracic levels in our clinic during 5 yearswere evaluated retrospectively. RESULTS In 25 patients, 6 to 82 years old,total 54 laminar screws were used. Most frequent diagnoses were cervical spinal stenosis and craniovertebraljunction anomalies.There were handicaps to perform other type of screwsin 19 out of 25 screws during first 4 years, and 9 out of 29 in the last year (p=0.0009).Two modifications were performed in some cases. In 4 segments with thin lamina, a shorter screw was performed to leave clear the thinnest part, and in 3 C2 levels with almost full length bifid spinous process,shorter screws were inserted from medial sides of the bifid processes with a more vertical orientation. There was ventral cortex penetration in 11 screws without new neurological deficits. One of them was removed because of its full thickness insertion into the spinal canal.Fusion rate was 75% in 16 patients followed radiologically longer than 6 months.In one patient out of 4 without fusion, unilateral screw was loosened, and in others laminar screws were not loosened. CONCLUSION Laminar screw technique is easy, safe and effective at C2, C7 and upper thoracic levels. Some modifications may be required due to the anatomical variations.It can be used at other subaxial levels also in theselected cases that other techniques could not be performed.
منابع مشابه
Laminar screw fixation in the subaxial cervical spine: A report on three cases
Although laminar screw fixation is often used at the C2 and C7 levels, only few previous case reports have presented the use of laminar screws at the C3-C6 levels. Here, we report a novel fixation method involving the use of practical laminar screws in the subaxial spine. We used laminar screws in the subaxial cervical spine in two cases to prevent vertebral artery injury and in one case to min...
متن کاملPosterior occipito-axial fixation applied C2 laminar screws for pediatric atlantoaxial instability caused by Down syndrome: Report of 2 cases
BACKGROUND Upper cervical spine instability is one of the most critical orthopedic problems in patients with Down syndrome. However, arthrodesis of the upper cervical spine in these patients can be very difficult to achieve and has a high complication rate because of mental retardation and accompanying various medical conditions of the vital organs. Even now, surgeries in such patients, especia...
متن کاملFeasibility of laminar screw placement in the upper thoracic spine: analysis using 3-dimensional computed tomographic simulation.
STUDY DESIGN Evaluation using 3-dimensional screw trajectory software and computed tomographic scans. OBJECTIVE To investigate the anatomic feasibility of laminar screw placement in the upper thoracic spine compared with pedicle screw placement. SUMMARY OF BACKGROUND DATA Although laminar screws have been suggested as an alternative to pedicle screws in the upper thoracic spine, previous an...
متن کاملA biomechanical comparison of a novel thoracic screw fixation method: transarticular screw fixation vs traditional pedicle screw fixation.
BACKGROUND Transarticular screw fixation is used in the upper cervical and lumbar spine to achieve posterior spinal stability, and its biomechanical performance has been proven to be similar to that of pedicle screw fixation. However, few studies have reported the use of transarticular screw fixation in the upper thoracic spine. OBJECTIVE To biomechanically compare transarticular screws with ...
متن کاملPosterior cervical spine arthrodesis with laminar screws: a report of two cases.
We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Turkish neurosurgery
دوره شماره
صفحات -
تاریخ انتشار 2017