Three-dimensional echocardiographic planimetry of maximal regurgitant orifice area in myxomatous mitral regurgitation: intraoperative comparison with proximal flow convergence.
نویسندگان
چکیده
OBJECTIVES We sought to validate direct planimetry of mitral regurgitant orifice area from three-dimensional echocardiographic reconstructions. BACKGROUND Regurgitant orifice area (ROA) is an important measure of the severity of mitral regurgitation (MR) that up to now has been calculated from hemodynamic data rather than measured directly. We hypothesized that improved spatial resolution of the mitral valve (MV) with three-dimensional (3D) echo might allow accurate planimetry of ROA. METHODS We reconstructed the MV using 3D echo with 3 degrees rotational acquisitions (TomTec) using a transesophageal (TEE) multiplane probe in 15 patients undergoing MV repair (age 59 +/- 11 years). One observer reconstructed the prolapsing mitral leaflet in a left atrial plane parallel to the ROA and planimetered the two-dimensional (2D) projection of the maximal ROA. A second observer, blinded to the results of the first, calculated maximal ROA using the proximal convergence method defined as maximal flow rate (2pi(r2)va, where r is the radius of a color alias contour with velocity va) divided by regurgitant peak velocity (obtained by continuous wave [CW] Doppler) and corrected as necessary for proximal flow constraint. RESULTS Maximal ROA was 0.79 +/- 0.39 (mean +/- SD) cm2 by 3D and 0.86 +/- 0.42 cm2 by proximal convergence (p = NS). Maximal ROA by 3D echo (y) was highly correlated with the corresponding flow measurement (x) (y = 0.87x + 0.03, r = 0.95, p < 0.001) with close agreement seen (AROA (y - x) = 0.07 +/- 0.12 cm2). CONCLUSIONS 3D echo imaging of the MV allows direct visualization and planimetry of the ROA in patients with severe MR with good agreement to flow-based proximal convergence measurements.
منابع مشابه
Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.
BACKGROUND Analogous to stenotic valve area in the assessment of valvular stenosis, regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular insufficiency. However, this parameter has not been routinely available up to now. In this study, we introduce the concept and provide the methodology to calculate regurgitant orifice area noninvasively, based on the analysis of...
متن کاملValidation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis.
BACKGROUND It has been proposed recently that measuring the flow convergence region proximal to an orifice by Doppler flow mapping can provide a means of calculating regurgitant flow rate. Although verified in experimental models, this approach is difficult to validate clinically because there is no ideal gold standard for regurgitant flows in patients. However, this method also can be used to ...
متن کاملReal‐Time 3‐Dimensional Echocardiographic Assessment of Effective Regurgitant Orifice Area in Dogs With Myxomatous Mitral Valve Disease
BACKGROUND Effective regurgitant orifice area (EROA), calculated from the vena contracta width (VCW) as the narrowest portion of the proximal regurgitant jet, might be used to estimate severity of mitral regurgitation. However, this simplified assumption only holds when the EROA is circular, which might not be true in dogs with myxomatous mitral valve disease (MMVD). HYPOTHESIS Effective regu...
متن کاملProximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: a core review.
The proximal isovelocity surface area (PISA) measurement, also known as the "flow convergence" method, can be used in echocardiography to estimate the area of an orifice through which blood flows. It has many applications, but this review focuses only on its use in the intraoperative evaluation of mitral regurgitation. In that setting, PISA provides a quantitative assessment of the severity of ...
متن کاملPhysiologic Application of the Proximal Flow Convergence Method: Clinical Data and Experimental Testing
Background The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1998