Evaluation of the Hemochron 8000 Rx / Dx System for Heparin Management Howard
نویسنده
چکیده
The Hemochron Rx/Dx uses an ACT and a heparin response tube to calculate the heparin dose to identify heparin sensitive/resistant patients. We evaluated the Rx/Dx system in 37 patients to determine if the ACT after the predicted heparin loading dose was adequate to initiate CPB. The mean heparin dose calculated by the Rx/Dx was 31,700 IU ± 8,700 IU (370 IU/kg) with a mean post ACT of 463 ± 124 sec. Our standard heparin dose (400 IU/kg) would have given an additional2,800 IU over the Rx/Dx. Four patients (6.5%) were predicted to be heparin sensitive and all four achieved an ACT over 450 sec. Twenty-one patients (56.8%) were predicted to be resistant and yet failed to raise the ACT over 450 sec in 17 (81.0% ). Twelve patients (32.4%) were predicted to have a normal heparin response, and four (33.3%) did not achieve an ACT over 450 sec. In all, 21 patients (56.8%) did not achieve an ACT greater than 450 sec. Each institution should evaluate their heparin loading dose and the resultant ACT. In this study, we found the number of times the Rx/Dx system did not raise the ACT over 450 sec too great to justify the additional expense. Volume 29, Number 2, june 1997 Address correspondence to: Howard D. Johnson, RRT, CCP Physician's Center Foothills Cardiothoracic Surgeons Suite 300 101 East Wood Street Spartanburg, SC 29303
منابع مشابه
The Hemochron Response RxDx heparin and protamine dosing system.
The use of dosing assays to calculate heparin and protamine dose requirements during cardiac surgery has been shown to significantly improve overall postoperative patient outcome. When patients are managed with an individualized dosing system, intraoperative and postoperative transfusion requirements and bleeding are reduced. The Hemochron RxDx system is widely used as a complement to tradition...
متن کاملValidation of a new whole blood coagulation monitoring system.
The Hemochron Response is a third generation point-of-care (POC) whole blood coagulation analyzer that retains the clinical utility of the Hemochron standard (801/8000) while providing a data management program that assists the POC coordinator with Quality Assurance (QA) compliance. Clinical and laboratory studies were performed to ensure consistency of the target anticoagulation times with the...
متن کاملHand-Held Personal Digital Assistant Program for the HEMOCHRONregistered RxDxregistered Heparin and Protamine Dosing System
The use of in vitro dosing assays for heparin and protamine during cardiac surgery has significantly improved overall postoperative patient outcome. The HEMOCHRON RxDx system (International Technidyne Corp, Edison, NJ) is widely used for anticoagulation management. Based on a series of consecutive in vitro tests, the RxDx system is used to quantify the patient’s heparin requirement (heparin res...
متن کاملInhibitor (DX-9065a): Implications for Interventional Use
Heparin has been conventionally used as an anticoagulant for medical and surgical indications. Because factor Xa is an essential component of the prothrombinase complex and leads to the generation of thrombin, its inhibition has become a focus of newer antithrombotic drug development. The in vitro anticoagulant profile of DX-9065a, a synthetic direct factor Xa inhibitor, was studied using activ...
متن کاملA four-year experience with patient individualized heparin and protamine dosing using the Hemochron RxDx system.
Cardiac surgical case histories, collected over 4 years at Huntsville Hospital in Alabama, were reviewed for 2,293 patients. Patients were separated into two dosing groups for both heparin and protamine, hospital empirically dosed and Hemochron RxDx dosed. Review of the heparin dosing information found that incomplete data were collected for 47 patients, leaving 2,246 patients eligible to be ev...
متن کامل