Template-based Quality Assessment of the Doppler Ultrasound Signal for Fetal Monitoring
نویسندگان
چکیده
One dimensional Doppler Ultrasound (DUS) is a low cost method for fetal auscultation. However, accuracy of any metrics derived from the DUS signals depends on their quality, which relies heavily on operator skills. In low resource settings, where skill levels are sparse, it is important for the device to provide real time signal quality feedback to allow the re-recording of data. Retrospectively, signal quality assessment can help remove low quality recordings when processing large amounts of data. To this end, we proposed a novel template-based method, to assess DUS signal quality. Data used in this study were collected from 17 pregnant women using a low-cost transducer connected to a smart phone. Recordings were split into 1990 segments of 3.75 s duration, and hand labeled for quality by three independent annotators. The proposed template-based method uses Empirical Mode Decomposition (EMD) to allow detection of the fetal heart beats and segmentation into short, time-aligned temporal windows. Templates were derived for each 15 s window of the recordings. The DUS signal quality index (SQI) was calculated by correlating the segments in each window with the corresponding running template using four different pre-processing steps: (i) no additional preprocessing, (ii) linear resampling of each beat, (iii) dynamic time warping (DTW) of each beat and (iv) weighted DTW of each beat. The template-based SQIs were combined with additional features based on sample entropy and power spectral density. To assess the performance of the method, the dataset was split into training and test subsets. The training set was used to obtain the best combination of features for predicting the DUS quality using cross validation, and the test set was used to estimate the classification accuracy using bootstrap resampling. A median out of sample classification accuracy on the test set of 85.8% was found using three features; template-based SQI, sample entropy and the relative power in the 160 to 660 Hz range. The results suggest that the new automated method can reliably assess the DUS quality, thereby helping users to consistently record DUS signals with acceptable quality for fetal monitoring.
منابع مشابه
Advances in Doppler Ultrasound Signal Processing for Fetal Monitoring
The fetal monitoring is based on a fetal heart rhythm analysis, and aimed at the detection of early symptoms of the intrauterine fetal hypoxia. The most often used method for acquisition of the fetal heart rate (FHR) during pregnancy is the Doppler ultrasound technique. When a penetrating beam is reflected from the moving parts, like valves of the fetal heart, its frequency is shifted according...
متن کاملFetal Cardiac Doppler Signal Processing Techniques: Challenges and Future Research Directions
The fetal Doppler Ultrasound (DUS) is commonly used for monitoring fetal heart rate and can also be used for identifying the event timings of fetal cardiac valve motions. In early-stage fetuses, the detected Doppler signal suffers from noise and signal loss due to the fetal movements and changing fetal location during the measurement procedure. The fetal cardiac intervals, which can be estimate...
متن کاملA novel technique for fetal heart rate estimation from Doppler ultrasound signal
BACKGROUND The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal,...
متن کاملBiological Effect of Modern Fetal Ultrasound Techniques on Human Dermal Fibroblast Cells
Background: Diagnostic ultrasound has been used to detect human disease especially fetus abnormalities in recent decades. Although the harmful effects of diagnostic ultrasound on human have not been established so far, several researchers showed it has had bioeffects in cell lines and in experimental animals. Three-dimensional (3D), four-dimensional (4D), and color Doppler sonography are new te...
متن کاملComparative Assessment of Ultrasound Placental Findings in Small for Gestational Age and Normal-Weight Fetuses
Background Small for gestational age (SGA) refers to newborns whose birth weight is less than the 10th percentile for gestational age. The aim of this study was to provide a comparative assessment of ultrasound placental findings in SGA and normal-weight fetuses in singleton pregnant women. Materials and Methods In...
متن کامل