Continuous-Flow Left Ventricular Assist Device Thrombosis: A Danger Foreseen is a Danger Avoided
نویسندگان
چکیده
Left ventricular assist devices (LVAD) are an increasingly implemented therapeutic intervention for patients with end-stage heart failure. A growing body of evidence, however, has shown an elevated risk of device thrombosis, a major complication jeopardizing the patient's post-implantation survival. To date, multiple causative factors for LVAD thrombosis have been identified, such as internal shear stress, device material, infection, and inadequate anticoagulation. Understanding the mechanisms leading to LVAD thrombosis will not only enable device optimization, but also allow for better patient handling, hence improving post-implantation outcome. In this review we highlight the most commonly identified factors leading to LVAD thrombosis and discuss their mechanisms.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملLigation of the Outflow Graft of the Left Ventricular Assist Device for Management of Hemolysis Due to Pump Thrombosis
Pump thrombosis is a serious complication of continuous-flow left ventricular assist devices (LVAD). Treatment options include medical thrombolysis, surgical pump exchange or urgent heart transplantation. We are reporting a case of pump thrombosis with active hemolysis and acute renal failure managed surgically by isolating the LVAD while awaiting renal recovery and donor heart availability.
متن کاملLeft ventricular-assist device arrest: total thrombosis of a continuous flow left ventricular-assist device.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/ehjci/jev290 Online publish-ahead-of-pr...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملWatchful Waiting in Continuous-Flow Left Ventricular Assist Device Patients With Ongoing Hemolysis Is Associated With an Increased Risk for Cerebrovascular Accident or Death
Continuous-flow left ventricular assist devices (CF-LVADs) have led to a significant improvement in the survival of patients with end stage heart failure. However, CF-LVAD use is complicated by numerous serious adverse events, with bleeding and thrombosis accounting for 51.3% of readmissions. Device thrombosis in particular is a feared complication of long-term CF-LVAD support, occurring in ≈10...