Characterizing exhaled airflow from breathing and talking.

نویسندگان

  • Jitendra K Gupta
  • Chao-Hsin Lin
  • Qingyan Chen
چکیده

UNLABELLED The exhaled air of infected humans is one of the prime sources of contagious viruses. The exhaled air comes from respiratory events such as the coughing, sneezing, breathing and talking. Accurate information on the thermo-fluid characteristics of the exhaled airflow can be important for prediction of infectious disease transmission. The present study developed a source model to provide the thermo-fluid conditions of the exhaled air from the breathing and talking processes. The source model is a set of equations obtained from the measurements of the flow rate, flow direction, and area of mouth/nose opening with human subjects. It was found that the exhaled flow rate over time can be represented as a sinusoidal function for breathing and a constant for talking. The flow rates can be calculated by physiological parameters of a subject. The direction of the exhalation jet did not vary much between subjects and the area of mouth/nose opening could be regarded as a constant. Though the mouth/nose opening size varied among subjects, they were not correlated with the physiological parameters of the subjects. If combined with appropriate virus and droplet distribution information, the model can be used to describe the disease source due to breathing and talking. PRACTICAL IMPLICATIONS Accurate prediction of airborne disease transmission, and the infection prone zones, can aid in identifying and implementing the control strategies. With the recent advancements, Computational Fluid Dynamics (CFD) has become a powerful tool in predicting the disease transmission. Accurate prediction of the transmission by these CFD simulations requires information on sources and sinks of infectious viruses and models for dispersion of these viruses. The exhaled air of an infected human is one of the prime sources of disease viruses. In the present study, measurements of the flow were conducted on human subjects to develop models for the flow boundary conditions for the exhalation and inhalation during breathing and talking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Numerical Simulation of Inspiratory Airflow in Human Airways during Exercise at Sea Level and at High Altitude

At high altitudes, the air pressure is much lower than it is at sea level and contains fewer oxygen molecules and less oxygen is taken in at each breath. This requires deeper and rapid breathing to get the same amount of oxygen into the blood stream compared to breathing in air at sea level. Exercises increase the oxygen demand and make breathing more difficult at high altitude. In this study, ...

متن کامل

Design and test of a new tracheostoma valve based on inhalation.

BACKGROUND Tracheostoma valves are used to make hand-free speaking possible for persons who have undergone a laryngectomy. OBJECTIVE To design and test a new tracheostoma valve to improve existing tracheostoma valves. METHODS The tracheostoma valve closes by means of strong inhalation so that all the air that is exhaled is available for phonation. The device automatically stays in the"speak...

متن کامل

An Ultrasonic Contactless Sensor for Breathing Monitoring

The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respir...

متن کامل

A new method for sampling and detection of exhaled respiratory virus aerosols.

We have developed a mask sampler for exhaled respiratory viruses. Among a group of 9 patients with cold symptoms who had virus-positive nasal mucus specimens, as analyzed by multiplexed polymerase chain reaction, virus-positive mask samples were obtained after coughing (20 times), talking (20 min), or breathing (20 min) from 6, 5, and 3 patients, respectively.

متن کامل

Simplified models for exhaled airflow from a cough with the mouth covered.

UNLABELLED Covering a cough can be useful in reducing the transmission of airborne infectious diseases. However, no simple method is available in the literature for predicting the exhaled airflow from a cough with the mouth covered. This investigation used smoke to visualize the airflow exhaled by 16 human subjects. Their mouths were covered by a tissue, a cupped hand, a fist, and an elbow with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2010