Proteus Mediastinitis Causing Fatal Pseudoaneurysm following Aortic Valve Replacement

نویسندگان

  • Sarfraz Nazir
  • John Jeffery
  • Alexandra-Alice Tenovici
  • Horace D'Costa
چکیده

We report an unusual case of Gram-negative mediastinitis following aortic valve replacement via median sternotomy. The patient presented two months after surgery following a urinary tract infection in septic shock with a discharging sternal wound and blood cultures positive for Proteus mirabilis. Imaging revealed a large anterior mediastinal abscess and aortic pseudoaneurysm which subsequently ruptured resulting in fatality. Gram-negative mediastinitis is a rare complication of cardiac surgery that can present late following initial clinical improvement and should be considered when "remote site" infections are present. Computerised Tomography scanning has a role to play in the identification of this.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudoaneurysm of the ascending aorta after aortic valve replacement.

A 58-year-old man with fever and chest wall tenderness was seen 8 weeks after aortic valve replacement. His initial postoperative course had been complicated by mediastinitis, requiring antibiotics and surgical debridement. A transthoracic echocardiogram did not reveal the culprit lesion. Pseudoaneurysm of the ascending aorta was suspected, based on computerized tomographic and magnetic resonan...

متن کامل

An aortic root pseudoaneurysm that developed after implantation of a rectus abdominis muscle flap to treat an MRSA mediastinitis: a case report.

The occurrence of mediastinitis following synthetic vascular replacement surgery is still associated with an unfavorable prognosis in the treatment of thoracic aortic diseases. This time we report a Bentall procedure that we re-performed to treat an aortic root pseudoaneurysm, which developed after a postoperative mediastinitis. This followed the first Bentall procedure, which was treated by de...

متن کامل

سودوآنوریسم فیستولیزه شده فیبروز بین دریچه ای میترال و آئورت در یک بیمار پس از عمل جراحی بای پس عروق کرونر

Pseudoaneurysm is a rare condition in the region of the fibrous body between the mitral and aortic valve, the mitral-aortic intervalvular fibrosa (MAIVF), that has been reported as a sequela of endocarditis and surgical trauma. MAIVF rarely occurs on native aortic valve after infective endocarditis (IE). It is often fatal because of its rapid progress, high rates of rupture and recurrence, and ...

متن کامل

Pseudoaneurysm of the mitral-aortic intervalvular fibrosa following aortic valve replacement - diagnosis and dynamic evaluation with multidetector CT and transesophageal echocardiography.

Sixteen-slice multidetector CT findings of a pulsatile pseudoaneurysm of the mitral-aortic intervalvular fibrosa, in a woman following aortic valve replacement, are presented. Multidetector CT depicted the pseudoaneurysm and enabled dynamic evaluation of its lumen through the cardiac cycle, documenting expansion during systole and almost complete collapse during diastole. This case illustrates ...

متن کامل

Two-Stage Procedure for Infected Aortic Graft Pseudoaneurysm: 10-Year Follow Up after Omental Prosthesis Wrapping.

Prosthetic graft infections with mediastinitis following aortic surgery are rare, yet represent grave complications yielding high morbidity and mortality. We present the case of a 57-year-old female patient with past history of emergent surgery for iatrogenic Type A dissection treated by supracoronary ascending aortic replacement. Four months after the initial surgery, a sternal fistula had for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013