Preliminary results of nonfluoroscopy-based 3D navigation for neurointerventional procedures.

نویسندگان

  • Sonia Pujol
  • Kai Frerichs
  • Alexander Norbash
  • Ron Kikinis
  • Carl-Fredrik Westin
چکیده

PURPOSE To investigate the capabilities of a neurovascular navigation prototype in phantom experiments. MATERIALS AND METHODS The proposed navigation system integrates three-dimensional (3D) visualization of the anatomy and real-time electromagnetic localization of the endovascular tools. A 3D model of an endovascular phantom was reconstructed from thresholded preprocedural computed tomographic (CT) data. The vascular model was aligned with the reference frame of an electromagnetic tracker by using paired-point matching based on eight external fiducials. The robustness and accuracy of the registration were evaluated in 29 experiments. A magnetically tracked catheter was inserted into the carotid artery of the phantom, and the navigation system was used to reach five predefined vascular landmarks. The spatial accuracy of the prototype was evaluated during 50 endovascular targeting attempts. RESULTS The navigation system achieved accurate co-registration of the location of a catheter inside a 3D reconstruction of a phantom vasculature. The experiments demonstrated the robustness of the registration, with a standard deviation for the translation and rotation components of 0.7 mm and 0.3 degrees , respectively. The maximal average error on the fiducials was 3.2 mm. Endovascular navigation by using the 3D real-time display was successfully performed with a mean overall accuracy of 2.7 mm +/- 0.7 and no projection limitation. CONCLUSION The authors developed a navigation system that provides real-time 3D visualization of the position of endovascular components in a neurovascular phantom. The preliminary in vitro experiments showed clinically acceptable accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

designing and implementing a 3D indoor navigation web application

​During the recent years, the need arises for indoor navigation systems for guidance of a client in natural hazards and fire, due to the fact that human settlements have been complicating. This research paper aims to design and implement a visual indoor navigation web application. The designed system processes CityGML data model automatically and then, extracts semantic, topologic and geometric...

متن کامل

Transradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note

Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...

متن کامل

CT (ISO-C-3D) image based computer assisted navigation in trauma surgery: A preliminary report

Introduction: CT (ISO-C-3D) image based navigation has recently been introduced to improve the image quality and accuracy during computer assisted orthopaedic surgeries. We report on our early experience using this novel technique in intraarticular lower extremity fracture management. Methods: Real time CT-based navigation assisted surgery was used in the treatment of five patients with fractur...

متن کامل

Multimodal angiographic assessment of cerebral arteriovenous malformations: a pilot study

PURPOSE We describe our protocol of three-dimensional (3D) Roadmap intracranial navigation and image fusion for analysis of the angioarchitecture and endovascular treatment of brain arteriovenous malformations (AVMs). METHODS We performed superselective catheterization of brain AVMs feeders under 3D-Roadmap navigation. Angiograms of each catheterized artery on two registered orthogonal views ...

متن کامل

Engineering Critical Assessments of Marine Pipelines with 3D Surface Cracks Considering Weld Mismatch

Offshore pipelines are usually constructed by the use of girth welds, while welds may naturally contain flaws. Currently, fracture assessment procedures such as BS 7910 are based on the stress-based methods and their responses for situations with large plastic strain is suspicious. DNV-OS-F101 with limited modifications proposes a strain-based procedure for such plastic loads. In this paper 3D ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 18 2  شماره 

صفحات  -