Flow resistance of expiratory positive-pressure systems.

نویسندگان

  • M R Pinsky
  • D Hrehocik
  • J A Culpepper
  • J V Snyder
چکیده

We measured the flow-resistance of five commercially available 10 cm H2O expiratory positive-pressure (EPP) valves (n = five per valve type) at bias flows of between 0 and 2,000 ml/s. We found that individual valves of each type and manufacturer functioned similarly. Different valve types, however, functioned differently: with one type, system pressure was higher than rated (p less than 0.05), and with another type, system pressure was significantly flow-dependent (p less than 0.01). The remaining types of valves had no flow-resistive properties and maintained a system pressure of 10 cmH2O. We conclude that system pressure is not similar in all continuous positive airway pressure (CPAP) systems using bias flow and EPP valves. The work of breathing imposed by CPAP circuits will be increased in systems whose EPP valves have flow-dependent properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow resistance of expiratory positive-pressure valve systems.

The flow-resistive characteristics of a variety of commercially available expiratory positive-pressure valve systems used to provide continuous positive airway pressure (CPAP) and positive end-expiratory pressure were evaluated. One flow-resistor and seven threshold-resistor expiratory pressure valve systems were set at 5, 10, 15, 20, and 25 cm H2O of expiratory pressure, and sinusoidal exhaled...

متن کامل

Heavy snoring with upper airway resistance syndrome may induce intrinsic positive end-expiratory pressure.

We studied eight heavy snorers with upper airway resistance syndrome to investigate potential effects of sleep on expiratory airway and lung resistance, intrinsic positive end-expiratory pressure, hyperinflation, and elastic inspiratory work of breathing (WOB). Wakefulness and non-rapid-eye-movement sleep with high- and with low-resistance inspiratory effort (H-RIE and L-RIE, respectively) were...

متن کامل

Demand and continuous flow intermittent mandatory ventilation systems.

A mechanical lung was used to evaluate the pressure and flow characteristics of four demand and two continuous flow intermittent mandatory ventilation (IMV) systems. The amount of negative pressure required to initiate inspiratory flow and peak expiratory resistance were measured. The inspiratory pressure required to initiate flow in the demand mode was also compared to pressures generated in t...

متن کامل

Comparing airways clearance techniques in chronic obstructive pulmonary disease and bronchiectasis: positive expiratory pressure or temporary positive expiratory pressure? A retrospective study

BACKGROUND Airway clearance techniques include positive expiratory pressure, commonly used in our clinical practice, and a recently introduced temporary positive expiratory pressure device called UNIKO®. It is unclear which one provides the best benefit to patients. OBJECTIVES The aim of this observational 4-year study was to retrospectively compare the efficacy of and specific indications fo...

متن کامل

Expiratory automatic endotracheal tube compensation reduces dynamic hyperinflation in a physical lung model

INTRODUCTION The effect of expiratory endotracheal tube (ETT) resistance on dynamic lung inflation is unknown. We hypothesized that ETT resistance causes dynamic lung hyperinflation by impeding lung emptying. We further hypothesized that compensation for expiratory ETT resistance by automatic tube compensation (ATC) attenuates dynamic lung hyperinflation. METHODS A ventilator equipped with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 94 4  شماره 

صفحات  -

تاریخ انتشار 1988