In situ polar organic chemical integrative sampling (POCIS) of steroidal estrogens in sewage treatment works discharge and river water.

نویسندگان

  • Thitima Rujiralai
  • Ian D Bull
  • Neville Llewellyn
  • Richard P Evershed
چکیده

A passive sampler (the polar organic chemical integrative sampler; POCIS) was assessed for its ability to sample natural estrogens (17β-estradiol, E2; estrone, E1 and estriol, E3) and the synthetic estrogen (17α-ethynylestradiol, EE2) in the outlet of a sewage treatment works over several weeks. The performance of the POCIS was investigated and optimised in the laboratory before field deployment with high recoveries (66-99%) were achieved for all estrogens. Moreover, it was shown that POCIS does not exhibit any preferential selectivity towards any of the target compounds. The sampling rates of E1, E2 and E3 were 0.018 ± 0.009, 0.025 ± 0.014 and 0.033 ± 0.019 L d(-1), respectively. Following field deployments of 28 days in the discharge of a sewage works, POCIS was shown to enhance the sensitivity of estrogen detection, especially for E3, and provide time-weighted average (TWA) concentrations of E1, E2 and E3, ranging from undetectable to 12 ng L(-1) upstream of the outflow of a sewage treatment works, 13 to 91 ng L(-1) at the outflow and 8 to 39 ng L(-1) downstream of the outflow. This revealed that E1, E2 and E3 are not completely removed during sewage treatment, with concentrations most likely being maintained by contributions from conjugated estrogen analogues. Grab water samples showed considerable variation in the concentrations of estrogens over a longer period (6 months). The results confirm that POCIS is an effective and non-discriminatory method for the detection of low concentrations of estrogens in the aquatic environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polar organic chemical integrative sampler (POCIS): application for monitoring organic micropollutants in wastewater effluent and surface water.

In this paper, we discuss the advantages and drawbacks of POCIS (Polar Organic Chemical Integrative Sampler) for the evaluation of river water quality downstream of wastewater treatment plants. POCIS proved well adapted to sampling alkylphenols and several pharmaceuticals. Concentration factors and the decrease in limits of quantification, compared to grab water sample analyses, were significan...

متن کامل

Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration.

Polar organic chemical integrative samplers (POCIS) are useful for monitoring a wide range of chemicals, including polar pesticides, in water bodies. However, few calibration data are available, which limits the use of these samplers for time-weighted average concentration measurements in an aquatic medium. This work deals with the laboratory calibration of the pharmaceutical configuration of a...

متن کامل

Determination of naproxen, ibuprofen and triclosan in wastewater using the polar organic chemical integrative sampler (POCIS): A laboratory calibration and field application

In this study, the occurrence in wastewater of two non-steroidal anti-inflammatory drugs (NSAIDs), naproxen and ibuprofen, and one personal care product, triclosan, was assessed using the polar organic chemical integrative sampler (POCIS). The samplers were initially calibrated in the laboratory to obtain sampling rates (Rs) for each target compound followed by deployment in the influent and ef...

متن کامل

Evaluation of an hPXR reporter gene assay for the detection of aquatic emerging pollutants: screening of chemicals and application to water samples.

Many environmental endocrine-disrupting compounds act as ligands for nuclear receptors. Among these receptors, the human pregnane X receptor (hPXR) is well described as a xenobiotic sensor to various classes of chemicals, including pharmaceuticals, pesticides, and steroids. To assess the potential use of PXR as a sensor for aquatic emerging pollutants, we employed an in vitro reporter gene assa...

متن کامل

Comparison between the polar organic chemical integrative sampler and the solid-phase extraction for estimating herbicide time-weighted average concentrations during a microcosm experiment.

Polar organic chemical integrative samplers (POCIS) were exposed for 9 days in two different microcosms that contained river waters spiked with deethylterbuthylazine, terbuthylazine and isoproturon. The experiment was performed with natural light and strong turbulence (flow velocities of about 15-50cms(-1)) for reproducing natural conditions. The concentrations were kept relatively constant in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental monitoring : JEM

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2011