A study of segment weight optimization with the CMS XiO step‐and‐shoot IMRT technique for prostate cancer
نویسندگان
چکیده
The aim of this study was to compare IMRT optimization in the CMS XiO radiotherapy treatment planning system, with and without segment weight optimization. Twenty-one prostate cancer patients were selected for this study. All patients were initially planned with step-and-shoot IMRT (S-IMRT). A new plan was then created for each patient by applying the segment weight optimization tool (SWO-IMRT). Analysis was performed on the (SWO-IMRT) and (S-IMRT) plans by comparing the total number of segments, monitor units, rectal and bladder dose. The study showed a statistically significant reduction in the total number of segments (mean: 25.3%; range: 16.8%-31.1%) with SWO-IMRT as compared to S-IMRT (p < 0.0001). Similarly, a mean reduction of 3.8% (range: 0.4%-7.7%) in the total MU was observed with SWO-IMRT (p < 0.0001). The study showed an average rectal dose decrease of 13.7% (range: 7.9%-21.4%) with SWO-IMRT (p < 0.0001). We also observed a statistically significant reduction of 26.7% (range: 16.0%-41.4%; p < 0.0001) in the mean dose to the posterior one-third rectum and an overall reduction in mean bladder dose of 2.2% (range: 0.1%-6.1%) for SWO-IMRT (p < 0.0001). This study shows that the segment weight optimization method significantly reduces the total number of segments and the dose to the rectum for IMRT prostate cancer. It also resulted in fewer monitor units for most of the prostate cases observed in this study.
منابع مشابه
Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملStep-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملWhat is the optimum minimum segment size used in step and shoot IMRT for prostate cancer?
Although the use of small segments in step and shoot IMRT provides better dose distribution, extremely small segments decrease treatment accuracy. The purpose of this study was to determine the optimum minimum segment size (MSS) in two-step optimization in prostate step and shoot IMRT with regard to both planning quality and dosimetric accuracy. The XiO treatment planning system and Oncor Impre...
متن کاملComparison of the KonRad IMRT and XiO treatment planning systems
Reducing the treatment time for IMRT patients is highly desirable. The objective of this work was to evaluate the new clinical Siemens KonRad inverse treatment planning system (TPS) and compare it to the CMS XiO TPS with special emphasis on the segmentation efficiency. For head and neck, liver and prostate cancer patients, step-and-shoot IMRT plans were designed using both CMS XiO and Siemens K...
متن کامل