Expression of random analytical error as a precentage of the range of clinical interest.
نویسنده
چکیده
I propose that random method error be expressed as a percentage of the range(s) of clinical interest (upper range limit minus lower range limit), in addition to its usual forms of presentation. The interpretation of this percent random error is simple because a given percentage error implies the same reliability, regardless of test or range of clinical interest. Two different upper limits for percent random analytical error are suggested, based on the medical application of the test and the statistical properties of various amounts of error. When the purpose of the test is to distinguish an upper medically defined limit from a lower medically defined limit, a maximum random error equivalent to 60% of the difference between the limits is proposed. If the purpose of the test is to monitor values in the neighborhood of a normal range or therapeutic range, an upper limit for random error equal to 20% of the difference between the limits of the range is suggested.
منابع مشابه
Evaluation of the total analytical error in the flame photometry method
Background and Objectives: For total analytical error, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. M...
متن کاملComparison of random and aligned PCL nanofibrous electrospun scaffolds on cardiomyocyte differentiation of human adipose-derived stem cells
Objective(s):Cardiomyocytes have small potentials for renovation and proliferation in adult life. The most challenging goal in the field of cardiovascular tissue engineering is the creation of an engineered heart muscle. Tissue engineering with a combination of stem cells and nanofibrous scaffolds has attracted interest with regard to Cardiomyocyte creation applications. Human adipose-derived s...
متن کاملمیزان افسردگی در دانشجویان پزشکی (اهواز – 1371)
Two random samples, consiting of 100 female and 100 male medical students stydying at medical school of Shahid Chamran University in Ahwaz were administered by Beck Depression Invemtory. Male students scored somewhat lower on BDI than the females but the difference was not significant. The same result was true when students enrolled in basic sciences courses and those in clinical courses were...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملAIOSC: Analytical Integer Word-length Optimization based on System Characteristics for Recursive Fixed-point LTI Systems
The integer word-length optimization known as range analysis (RA) of the fixed-point designs is a challenging problem in high level synthesis and optimization of linear-time-invariant (LTI) systems. The analysis has significant effects on the resource usage, accuracy and efficiency of the final implementation, as well as the optimization time. Conventional methods in recursive LTI systems suffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 22 4 شماره
صفحات -
تاریخ انتشار 1976