Calculable coaxial resistors for precision measurements

نویسنده

  • Randolph E. Elmquist
چکیده

Coaxial straight-wire resistors have been constructed with the purpose of improving comparisons between resistors, capacitors, and inductors in the audio frequency range. The design is based on the principle that a coaxial line with a cylindrical shield can be described by relatively simple equationsfor the real and imaginary parts of the impedance. The resistors, with values above 100 n, will be used as primary transfer standards for characterization offrequency dependence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal AC voltage standards with calculable AC-DC transfer difference in frequency range from 10 kHz to 1 MHz

Because Republic of Poland does not have its own primary AC voltage standard, we have been developing a set of standards which in the future can serve as national primary AC voltage standard. The set is composed of three standards with nominal input voltages UN of 1.5 V, 3 V and 6 V, respectively. The set covers AC voltage range from 0.7 V to 6 V. The voltage range will be extended to 0.5 ... 1...

متن کامل

Dielectrophoresis and electrohydrodynamics-mediated fluidic assembly of silicon resistors

In this letter, we present techniques, utilizing dielectrophoresis and electrohydrodynamics, which can be used for assembling single-crystal silicon devices suspended in a solution onto a binding site on a heterogeneous substrate. Silicon resistors with gold/chromium layers located at the end of the resistors and silicon blocks without metal were fabricated on bonded and etched-backed silicon-o...

متن کامل

Stability of Double-Walled Manganin Resistors

The resistance standard described by James L. Thomas [1] was the result of his extensive effort to develop a new standard by systematically investigating every factor affecting the stability of resistance— time, surface effects, temperature, power, pressure— detectable at the time. The result was a unique standard which was used as part of the National Reference Group of resistors beginning in ...

متن کامل

Sensitivity and Uncertainty Analysis for Calculable Antenna Factor of the Direct-feed Biconical Antenna

Antennas calibrations are required for EMC measurements that determine the radiated disturbance of a communications product, as well as household electronics and automotive equipment. Usually, the EMC test laboratory employs equipment calibrated by calibration laboratories. The important parameter during the antenna calibration is the Antenna Factor (AF). Basically, AF was determined and calibr...

متن کامل

CLEO-c Confronts High Precision Lattice QCD

We discuss new results and upcoming measurements by the CLEO-c collaboration, on decays of heavy quark mesons and on the properties of heavy quarkonia. In particular, we emphasize those measurements which are just now becoming calculable in unquenched Quantum ChromoDynam-ics (QCD) on the lattice. Our ultimate goal is to provide a testing ground for recent approaches to " high precision " Lattic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Instrumentation and Measurement

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2000