Dose measurement of cobalt-60 radiotherapy beams in treatment fields.
نویسندگان
چکیده
BACKGROUND Radiation-therapy is a complex process with multiple steps, each of which has an impact on the quality of treatment. Accurate dosimetry is a critical step during the radiotherapy of cancer patients.The aim of the present study was to measure and evaluate the doses of two cobalt- 60 (60Co) teletherapy units GWXJ80 of NPIC China and Theratron 780 of AECL Canada at various points within fields for different field sizes. METHODS This cross-sectional descriptive study was done to measure the 60Co doses in the treatment fields.The dose measurements were done in air and 30x30x30 cm3 Phantom at 80 cm SSD by using calibrated NE 2570 Farmer Electrometer & NE 2571 Farmer Ionization Chamber and percentage of doses were calculated. RESULTS The results showed that 60% central area of all fields ranging from 100-98.79% and 100-96.12% for GWXJ80 in the air and phantom, whereas for Theratron 780, they were ranging from 100-98.50% and 100-96.45% in air and phantom respectively. The percentages of doses at the edges for GWXJ80 and Theratron 780 in the air were 75.39-38.66% & 85.65-46.47% respectively and they were 82.22-40.39% & 49.05-24.55% respectively in phantom. CONCLUSIONS The doses within 60% central area of fields in air were higher than phantom for both teletherapy units. The doses at field edges in air were lower in GWXJ80 than Theratron 780 whereas in phantom they were vice versa. But all were in the acceptable range as recommended by International Commission on Radiation Units and Measurements.
منابع مشابه
Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملDosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کاملCalculation and Comparison of Heart Integral Dose in The Treatment of Esophagus Cancer with Three Photon Energies & Using CT Simulation and Treatment Planning System
Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a high incidence rate among other countries. Radiotherapy is one of the three methods (surgery, radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method of treatment, the organs such as heart and spinal cord are regarded as organs at r...
متن کاملAbsorbed Dose Calculation In Irregular Blocked Radiation Fields: Evaluation of Clarkson’s Sector Integration Method for Radiation Fields Commonly Used in Conventional Radiotherapy
Introduction: Irregular/blocked fields are routinely used in radiotherapy. The doses of these fields are usually calculated by means of equivalent square method that is inherently prone to uncertainty. On the other hand, Clarkson’s sector integration method is a dose calculation method which offers far better accuracy in dose calculation of irregular fields. The Scatter Air Ratio (SAR) of an in...
متن کاملThe Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Ayub Medical College, Abbottabad : JAMC
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2014