A comparison of methods for determining urea distribution volume for routine use in on-line monitoring of haemodialysis adequacy.

نویسندگان

  • Elizabeth J Lindley
  • Paul W Chamney
  • Andreas Wuepper
  • Helen Ingles
  • James E Tattersall
  • Eric J Will
چکیده

BACKGROUND The availability of haemodialysis machines equipped with on-line clearance monitoring (OCM) allows frequent assessment of dialysis efficiency and adequacy without the need for blood samples. Accurate estimation of the urea distribution volume 'V' is required for Kt/V calculated from OCM to be consistent with conventional blood sample-based methods. METHODS Ten stable HD patients were monitored monthly for 6 months. Time-averaged OCM clearance (K(OCM)) and pre- and post-dialysis blood samples were collected at each monitored session. The second generation Daugirdas formula was used to calculate the single-pool variable volume Kt/V, (Kt/V)(D). Values of V to allow comparison between OCM and blood-based Kt/V were determined from Watson's formula (V(Watson)), bioimpedance spectroscopy (V(BIS)), classical urea kinetic modelling (V(UKM_C)) and a simple computation of V (V(UKM_S)) from the blood-based Kt/V and K(OCM)t. RESULTS Comparison of K(OCM)t/V with (Kt/V)(D) shows that using V(Watson) leads to significant systematic underestimation of dialysis dose. K(OCM)t/V(BIS) agrees with (Kt/V)(D) to within +/- 10%. K(OCM)t/V(UKM_S) is, by definition, identical to (Kt/V)(D) when initially calculated. However, if a historical value of V is used, agreement between K(OCM)t/V and (Kt/V)(D) over 6 months varies by 5% for V(BIS) and 10% for V(UKM_S). CONCLUSIONS When investigating the effect of different treatment strategies on dialysis efficiency, any estimate of V can be used provided it is constant, as K is the relevant parameter. When frequent supervision of actual dialysis dose is required, the greatest consistency between K(OCM)t/V and the reference, Kt/V(D), over time is achieved with V(BIS).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Method of Location Identification and Determining the Effect of Each Flicker Source in Distribution Networks

Voltage flicker phenomenon is one of the main power quality problems in today's power networks. Before any compensation operation for this phenomenon, the location of each flicker sources must be identified and the effect of each of them on the network flicker value must be determined. Also, methods that require least number of monitoring points are more in demand due to the limitations of meas...

متن کامل

A new method of post-dialysis blood urea sampling: the 'stop dialysate flow' method.

BACKGROUND A standardized practical method of post-dialysis blood sampling is required to improve the precision of using urea kinetics in the evaluation of haemodialysis dose and to permit comparative audit. The methods recommended in the Renal Association and Dialysis Outcomes Quality Initiative (DOQI) guidelines reduce the blood pump speed to a low rate at the end of haemodialysis before bloo...

متن کامل

Monitoring of urban subway lines subsidence Using satellite radar interferometry method (Study area: Part of Tehran Metro Line 7)

Nowadays, satellite radar interferometry method plays an important role in calculating natural and artificial displacements, including displacements caused by floods, earthquakes, landslides, drilling of unauthorized wells, drilling of urban tunnels, etc. Metro tunneling is very important due to the importance of preventing irreparable financial and human losses. In Tehran, especially due to th...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

Equivalent continuous clearances EKR and stdK in incremental haemodialysis.

BACKGROUND Many haemodialysis patients have residual renal function (RRF), which as such is insufficient to maintain satisfactory quality of life but reduces the demands of treatment and improves outcomes. In incremental dialysis, the dose is adjusted according to RRF, but how should it be done? METHODS Urea generation rate (G) and distribution volume (V) were determined by the double-pool ur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2009