Timing of noninvasive ventilation failure: causes, risk factors, and potential remedies
نویسندگان
چکیده
BACKGROUND Identifying the predictors of noninvasive ventilation (NIV) failure has attracted significant interest because of the strong link between failure and poor outcomes. However, very little attention has been paid to the timing of the failure. This narrative review focuses on the causes of NIV failure and risk factors and potential remedies for NIV failure, based on the timing factor. RESULTS The possible causes of immediate failure (within minutes to <1 h) are a weak cough reflex, excessive secretions, hypercapnic encephalopathy, intolerance, agitation, and patient-ventilator asynchrony. The major potential interventions include chest physiotherapeutic techniques, early fiberoptic bronchoscopy, changing ventilator settings, and judicious sedation. The risk factors for early failure (within 1 to 48 h) may differ for hypercapnic and hypoxemic respiratory failure. However, most cases of early failure are due to poor arterial blood gas (ABGs) and an inability to promptly correct them, increased severity of illness, and the persistence of a high respiratory rate. Despite a satisfactory initial response, late failure (48 h after NIV) can occur and may be related to sleep disturbance. CONCLUSIONS Every clinician dealing with NIV should be aware of these risk factors and the predicted parameters of NIV failure that may change during the application of NIV. Close monitoring is required to detect early and late signs of deterioration, thereby preventing unavoidable delays in intubation.
منابع مشابه
Series 0noninvasive Ventilation in Acute and Chronic Respiratory
Equipment needs for noninvasive mechanical ventilation. B. Schönhofer, S. Sortor-Leger. #ERS Journals Ltd 2002. ABSTRACT: Noninvasive mechanical ventilation (NIV) has a long tradition for the treatment of chronic respiratory failure and more recently has also been applied in acute respiratory failure. Based on this experience both critical care ventilators and portable ventilators are used to p...
متن کاملFailure of noninvasive ventilation after lung surgery: a comprehensive analysis of incidence and possible risk factors.
OBJECTIVE Noninvasive ventilation has been successfully used after thoracic surgery. However, noninvasive ventilation fails in about 20% of patients. The aim of the study was to analyze episodes of noninvasive ventilation failure and to assess possible risk factors, while taking into account the performance of fiberoptic bronchoscopy for secretion management. METHODS From January 2006 to June...
متن کاملEarly Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure
Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...
متن کاملPredictors of survival in COPD patients with chronic hypercapnic respiratory failure receiving noninvasive home ventilation.
BACKGROUND Patients with COPD and chronic hypercapnic respiratory failure (CHRF) are at high risk, and noninvasive ventilation at home is increasingly being used. Knowledge of prognostic parameters under these conditions is limited but may be clinically helpful and highlight the role of noninvasive ventilation. METHODS In 188 patients with COPD (mean +/- SD FEV1, 31.0 +/- 9.6% of predicted; P...
متن کاملNoninvasive vs conventional mechanical ventilation in acute respiratory failure: a multicenter, randomized controlled trial.
STUDY OBJECTIVE Noninvasive mechanical ventilation (NIMV) is beneficial for patients with acute respiratory failure (ARF) when added to medical treatment. However, its role as an alternative to conventional mechanical ventilation (CMV) remains controversial. Our aim was to compare the efficacy and resource consumption of NIMV against CMV in patients with ARF. DESIGN A randomized, multicenter,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014