Load-related implant reaction of mini-implants used for orthodontic anchorage.

نویسندگان

  • André Büchter
  • Dirk Wiechmann
  • Stefan Koerdt
  • Hans Peter Wiesmann
  • Josef Piffko
  • Ulrich Meyer
چکیده

The purpose of this study was to determine the clinical and biomechanical outcome of two different titanium mini-implant systems activated with different load regimens. A total of 200 mini-implants (102 Abso Anchor and 98 Dual Top) were placed in the mandible of eight Göttinger minipigs. Two implants each were immediately loaded in opposite direction by various forces (100, 300 or 500 cN) through tension coils. Additionally, three different distances between the neck of the implant and the bone rim (1, 2 and 3 mm) were used. The different load protocols were chosen to evaluate the load-related implant performance. The load was provided by superelastic tension coils, which are known to develop a virtually constant force. Non-loaded implants were used as a reference. Following an experimental loading period of 22 and 70 days half of the minipigs were sacrificed, and implant containing bone specimens evaluated for clinical performance and implant stability. Implant loosing was found to be statistically dependent on the tip moment (TM) at the bone rim. Clinical implant loosing were only present when load exceeded 900 cN mm. No movement of implants through the bone was found in the experimental groups, for any applied loads. Over the two experimental periods the non-loaded implants of one type of implant had a higher stability than those of the loaded implants. Dual Top implants revealed a slightly higher removal torque compared with Abso Anchor implants. Based on the results of this study, immediate loading of mini-implants can be performed without loss of stability when the load-related biomechanics do not exceed an upper limit of TM at the bone rim.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Thread Design of Orthodontics Mini Implants on Their Stability - A Pilot Study

ObjectivesThis FEM study was conducted in order to investigate the effect of thread design of an orthodontic mini-implant on primary stability and strain pattern and magnitude in the surrounding bone structure during orthodontic loading. Materials and MethodsThe mini-implants by six different manufacturers such as Aarhus Mini-Implant (American Orthodontics), AbsoAnchor (Dentos), Dual-Top (Jeil ...

متن کامل

A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science

The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on orthodontic science, briefly. The searching category was performed on the Pubmed using MeSH words such as "dental (mini) implants, orthodontic anchorage procedures, and orthodontic appliances." After preliminary sketch, they were grouped as follow: Those evaluating (a...

متن کامل

Patient’s Perception of Pain in Treatment with Temporary Anchorage Devices (Micro-implant, Mini-implant and Mini-plate): Intragroup and Intergroup Analysis

Currently, temporary anchorage devices (TADs) are being used in orthodontic treatments for skeletal anchorages. However, patients remain apprehensive regarding the use of this novel concept in orthodontic procedures. The purpose of this study was to compare the differences and the change in pain perception after treatment using TADs (micro-implant, mini-implant and mini-plate). Fifty-seven TADs...

متن کامل

Titanium alloy orthodontic mini-implants: scanning electron microscopic and metallographic analyses.

Anchorage control is one of the determining factors of successful orthodontic mechanics. In mini-implants, fractures due to placement and removal have been related to implant design and titanium alloy quality. This study assessed the topography and microstructure of five brands of mini-implants (Neodent, SIN, Morelli, Conexao, Foresta Dent). Scanning electron microscopic analyses of the head, t...

متن کامل

A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage.

PURPOSE The aim of this prospective clinical study was to assess the risk factors associated with failure of mini-implants used for orthodontic anchorage. MATERIALS AND METHODS A total of 140 mini-implants in 44 patients, including 48 miniplates and 92 freestanding miniscrews, were examined in the study. A variety of orthodontic loads were applied. The majority of implants were placed in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2005