Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.
نویسندگان
چکیده
OBJECTIVES The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.
منابع مشابه
With Dilated Cardiomyopathy
The dynamics between mitral anulus motion, and, thus, motion of the base of the heart, and filling of the left atrium and ventricle were studied by Doppler echocardiography in 12 normal subjects and 28 patients with dilated cardiomyopathy. The normal motion of the mitral anulus is associated with two phases of inflow from the pulmonary veins. The first phase (J) of pulmonary venous inflow occur...
متن کاملEvaluation and prognostic significance of left ventricular diastolic function assessed by Doppler echocardiography in the early phase of a first acute myocardial infarction.
AIM To study the prognostic significance of left ventricular diastolic function evaluated by transmitral and pulmonary venous flow velocities obtained in the early phase of a first acute myocardial infarction in relation to later development of congestive heart failure. METHODS Pulsed Doppler echocardiography of transmitral and pulmonary venous flow was assessed in 65 consecutive patients wit...
متن کاملCor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report
Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium through restrictive opening to the low-pressure, dis...
متن کاملNoninvasive Detection of Left-Ventricular Systolic Dysfunction by Acoustic Cardiography in Atrial Fibrillation
Objectives. Assessment of left ventricular (LV) systolic function in patients with atrial fibrillation can be difficult. Acoustic cardiography provides several parameters for quantifying LV systolic function. We evaluated the ability of acoustic cardiography to detect LV systolic dysfunction in patients with and without atrial fibrillation. Design. We studied 194 patients who underwent acoustic...
متن کاملAltered left atrial compliance after atrial appendectomy. Influence on left atrial and ventricular filling.
Previous studies have shown regional differences in atrial distensibility. We studied 12 open-chest dogs to test the hypothesis that left atrial compliance is decreased after removal of the left atrial appendage and to determine the effect of altered atrial compliance on atrial reservoir and conduit function. Sonomicrometer crystal pairs were used to measure the long- and short-axis diameters o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 34 3 شماره
صفحات -
تاریخ انتشار 1999