Detection of a prosthetic aortic valvular abscess with indium-111-labeled leukocytes.

نویسندگان

  • E Oates
  • R C Sarno
چکیده

An unsuspected annular abscess at the base of a prosthetic aortic valve in a patient with endocarditis was identified by indium-111-labeled leukocyte scintigraphy alone. This highly sensitive and specific technique expediently demonstrated the surgically proven inflammatory focus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Edwardsiella tarda Endocarditis Confirmed by Indium-111 White Blood Cell Scan: An Unusual Pathogen and Diagnostic Modality

Edwardsiella tarda is a freshwater marine member of the family Enterobacteriaceae which often colonizes fish, lizards, snakes, and turtles but is an infrequent human pathogen. Indium-111- ((111)In-) labeled white blood cell (WBC) scintigraphy is an imaging modality which has a wide range of reported sensitivity and specificity (from 60 to 100% and from 68 to 92%, resp.) for diagnosing acute and...

متن کامل

Visualization of a Prosthetic Vascular Graft Due to Platelet Contamination During 111 1ndium-labeled Leukocyte Scintigraphy

A prosthetic axillo-femoral bypass graft was visualized during 111/n-labeled leukocyte scintigraphy in a patient referred for possible abdominal abscess. The presence of significant cardiac bloodpool activity raised the possibility that this uptake was due to deposition of contaminating labeled platelets rather than labeled leukocytes. An analysis of a small sample of the patient's blood confir...

متن کامل

Usefulness of indium-111-oxine-labeled leukocyte scintigraphy in diagnosis of inflammation associated with chronic aortic dissection.

BACKGROUND Patients with chronic aortic dissection require monitoring for indications of disease progression. In present study, inflammation adjacent to associated aortic wall was evaluated by indium-111-oxine-labeled leukocyte scintigraphy, scince inflammation of the blood vessel wall often associates with progression of chronic aortic dissection. METHODS AND RESULTS Fifteen patients with ao...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

Clinical importance of enteric communication with abdominal abscesses.

The dynamics of leucocytes in abdominal abscesses were studied using indium-111 autologous leucocyte scanning in 30 patients. Thirteen patients showing enteric drainage of leucocytes on delayed scans were characterised by a lack of abdominal localising signs and a low detection rate by ultrasound (25%). By contrast, 16 of 17 patients without enteric drainage had abdominal signs, and in these pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 94 4  شماره 

صفحات  -

تاریخ انتشار 1988