Colorimetric characterization of scanner by measures of perceptual color error
نویسندگان
چکیده
Two methods for colorimetric characterization of color scanner are proposed based on the measures of perceptual color difference error. The first method is used to minimize the total color differences between the actual and predicted color samples. The second one, which is a generalization of the existing cubic-root preprocessing technique, derives the mapping between the p’th root of scanner responses and Commission Internationale de l’Eclairage L a b (CIELAB) values. The experiment results indicate that the color accuracies of the proposed methods, especially the second one, are better than those of the traditional CIE XYZ (CIEXYZ)space-based characterization methods. © 2006 SPIE and IS&T. DOI: 10.1117/1.2199872
منابع مشابه
Colorimetric Scanner Calibration for Textiles by Neural-Network
In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...
متن کاملColorimetric Scanner Calibration for Textiles by Neural-Network
In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...
متن کاملMeasures of Goodness for Color Scanners
Color errors in scanners arise from two sources: the non-colorimetric nature of the scanner sensitivities and the measurement noise. Several measures of goodness have been used to evaluate scanners based on these errors. In this paper, the trustworthiness of these measures is studied through simulations. A new measure incorporating both the above sources of errors and providing excellent agreem...
متن کاملThe Effects of Illuminants and Standard Observers Combination on Relationship between Spectrophotometric Error and Colorimetric Inaccuracy
The colorimetric error depends on the spectrophotometric inaccuracy. In this paper, a new method is introduced for determining the relationship between spectrophotometric error and colorimetric inaccuracy. The error propagation in colorimetric parameter calculation is evaluated using a linear relation between variance of reflectance spectra and CIE tristimulus values. This linear formula ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- J. Electronic Imaging
دوره 15 شماره
صفحات -
تاریخ انتشار 2006