The effect of X‐ray beam distortion on the Edwards Sapien XT ™ trans‐catheter aortic valve replacement prosthesis
نویسندگان
چکیده
INTRODUCTION Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. METHODS Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. RESULTS When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. CONCLUSION Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.
منابع مشابه
Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses.
BACKGROUND A new generation of balloon-expandable valves (e.g. Edwards SAPIEN XT) enables the use of a decreased sheath size using the NovaFlex™ delivery system for transfemoral transcatheter aortic valve implantation (TAVI). However, there are few data analysing the efficacy and safety of this new prosthesis. AIMS To evaluate periprocedural and 30-day clinical outcomes using the Edwards SAPI...
متن کاملLate Paravalvular Aortic Regurgitation: Migration of the Valve or Late Recoil?
A 79-year-old man underwent trans-catheter aortic valve replacement for symptomatic severe aortic stenosis with a 26-mm Edwards SAPIEN XT valve. Immediately after valve deployment there was moderate amount of paravalvular leak. Post-dilation was performed with an additional 2 cc of volume, and the paravalvular leak was reduced to trace. Nine months later, trans-thoracic echocardiography reveale...
متن کاملTransfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: feasibility and 30-day outcomes.
OBJECTIVES The authors report the feasibility and 30-day outcomes of transfemoral aortic valve replacement (TAVR), using the Edwards SAPIEN (Edwards Lifesciences, Irvine, California) and Edwards SAPIEN XT (Edwards Lifesciences) prosthesis, implanted using exclusively local anesthesia and fluoroscopic guidance. BACKGROUND Transfemoral TAVR is often managed with general anesthesia. However, a s...
متن کاملTransaortic aortic valve replacement using the Edwards Sapien-XT Valve and the Medtronic CoreValve: initial experience.
INTRODUCTION Transcatheter aortic valve replacement (TAVR) is now an established treatment for certain patients with severe aortic valve stenosis (AS). However, as the number of patients screened for TAVR increases, many are found to have absolutely no option for peripheral artery access. Transaortic valve replacement (TAoVR) has been proposed as a new alternative route in patients deemed unsui...
متن کاملTranscatheter aortic valve implantation: current principles of patient and technique selection and future perspectives.
Surgical aortic valve replacement (AVR) is the conventional treatment for severe aortic stenosis (AS). However, a high operative mortality of 7% to 10% is well recognized in high-risk groups.1,2 Risk of AVR is increased by a number of factors, including increasing age, and comorbidities, such as heart failure, respiratory and renal disease, prior cardiac surgery, and need for concomitant corona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 62 شماره
صفحات -
تاریخ انتشار 2015