Measurement‐guided volumetric dose reconstruction for helical tomotherapy
نویسندگان
چکیده
It was previously demonstrated that dose delivered by a conventional linear accelerator using IMRT or VMAT can be reconstructed - on patient or phantom datasets - using helical diode array measurements and a technique called planned dose perturbation (PDP). This allows meaningful and intuitive analysis of the agreement between the planned and delivered dose, including direct comparison of the dose-volume histograms. While conceptually similar to modulated arc techniques, helical tomotherapy introduces significant challenges to the PDP formalism, arising primarily from TomoTherapy delivery dynamics. The temporal characteristics of the delivery are of the same order or shorter than the dosimeter's update interval (50 ms). Additionally, the prevalence of often small and complex segments, particularly with the 1 cm Y jaw setting, lead to challenges related to detector spacing. Here, we present and test a novel method of tomotherapy-PDP (TPDP) designed to meet these challenges. One of the novel techniques introduced for TPDP is organization of the subbeams into larger subunits called sectors, which assures more robust synchronization of the measurement and delivery dynamics. Another important change is the optional application of a correction based on ion chamber (IC) measurements in the phantom. The TPDP method was validated by direct comparisons to the IC and an independent, biplanar diode array dosimeter previously evaluated for tomotherapy delivery quality assurance. Nineteen plans with varying complexity were analyzed for the 2.5 cm tomotherapy jaw setting and 18 for the 1 cm opening. The dose differences between the TPDP and IC were 1.0% ± 1.1% and 1.1% ± 1.1%, for 2.5 and 1.0 cm jaw plans, respectively. Gamma analysis agreement rates between TPDP and the independent array were: 99.1%± 1.8% (using 3% global normalization/3 mm criteria) and 93.4% ± 7.1% (using 2% global/2 mm) for the 2.5 cm jaw plans; for 1 cm plans, they were 95.2% ± 6.7% (3% G/3) and 83.8% ± 12% (2% G/2). We conclude that TPDP is capable of volumetric dose reconstruction with acceptable accuracy. However, the challenges of fast tomotherapy delivery dynamics make TPDP less precise than the IMRT/VMAT PDP version, particularly for the 1 cm jaw setting.
منابع مشابه
High-dose pre-operative helical tomotherapy (54 Gy) for retroperitoneal liposarcoma
PURPOSE To evaluate the feasibility of pre-operative radiotherapy (54 Gy) with Helical Tomotherapy (HT) followed by surgery. METHODS AND MATERIALS Ten patients with non-metastatic resectable retroperitoneal liposarcomas were treated by pre-operative tomotherapy (54 Gy) and surgery. Clinical and biological toxicities were evaluated on the CTCAEV3.0 scale. For nine patients, delivered tomothera...
متن کاملDosimetric Evaluation of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Helical Tomotherapy for Hippocampal-Avoidance Whole Brain Radiotherapy
BACKGROUND Whole brain radiotherapy (WBRT) is a vital tool in radiation oncology and beyond, but it can result in adverse health effects such as neurocognitive decline. Hippocampal Avoidance WBRT (HA-WBRT) is a strategy that aims to mitigate the neuro-cognitive side effects of whole brain radiotherapy treatment by sparing the hippocampi while delivering the prescribed dose to the rest of the br...
متن کاملAn Overview on the Clinical Application of Radiobiological Modeling in Radiation Therapy of Cancer
Submit Manuscript | http://medcraveonline.com Abbreviations: TCP: Tumor Control Probability; NTCP: Normal Tissue Control Probability; LKB: Lyman Kutcher Burman; IGRT: Image Guided Radiation Therapy; IMRT: Intensity Modulated Radiation Therapy; SIB-IMRT: Simultaneous Integrated BoostIMRT; VMAT: Volumetric Modulated Arc Therapy; DA: Double Arc; SA: Single Arc; HT: Helical Tomotherapy; IFP: Improv...
متن کاملSU-E-T-592: Comparison of Low Dose Volume and Integral Dose in Rotational Arc Radiation Therapy Modalities.
PURPOSE To compare low dose volume and integral dose of various rotational arc radiation therapy modalities, including helical tomotherapy (HT) and other volumetric modulated arc therapies (VMAT). METHODS A digital cylindrical phantom and an anthropomorphic pelvic phantom were used in the study. HT treatment was planned on TomoTherapy Planning Station (Accuray) and VMAT plans were generated o...
متن کاملIdentification of Biologically Effective Dose-Volumetric Parameters That Predict Radiation-Induced Hepatic Toxicity in Patients Treated With Helical Tomotherapy for Unresectable Locally Advanced Hepatocellular Carcinoma
The purpose of this study is to identify dose-volumetric parameters that predict radiation-induced hepatic toxicity (RIHT) by analyzing the relationship between the biologically effective dose (BED) delivered to the normal liver and RIHT.The clinical and dosimetric data from 123 patients with unresectable hepatocellular carcinoma (HCC) treated with helical tomotherapy were analyzed. The median ...
متن کامل