New rapid assay for nafcillin in serum by spectrofluorometry.
نویسندگان
چکیده
A new, rapid method for measuring serum levels of nafcillin by spectrofluorometry is described. The method involves extraction of 2 ml of acidified serum with n-butyl chloride, subjecting the organic solvent layer to excitation at 340 nm, and measuring the relative intensity of emission fluorescence at 380 nm. An excellent linear correlation exists between serum levels of nafcillin and the relative intensity in a drug concentration range of 0.25 to 150 mug/ml. The results obtained by this spectrofluorometric technique are in complete accord with those obtained by the conventional microbiological assay using Staphylococcus aureus ATCC 6538P. The method is not interfered with by elevated levels of endogenous metabolic products or the presence of other drugs, including a number of antimicrobial agents. The assay is interfered with, however, by the presence of salicylates, for which appropriate correction can easily be made. A salicylate assay employing a spectrofluorometric technique is also described.
منابع مشابه
Value of serum tests in combined drug therapy of endocarditis.
Two in vitro tests, the serum killing level and the serum bactericidal rate assays, were evaluated for correlation with therapeutic efficacy in the rabbit model of Staphylococcus aureus endocarditis. Animals were treated with nafcillin alone and in combination with tobramycin or gentamicin. Both were effective therapies, but rapidity of vegetation sterilization by the single and combined regime...
متن کاملQuantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening
In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...
متن کاملEvaluation of a new set of Real-Time PCR for Brucella detection within human and animal samples
A quantitative TaqMn Real-Time PCR assay was developed and its diagnostic value on human serum and livestock samples were evaluated. Brucella species could be distributed through communities as a biological agent. Rapid detection of biological threat agents is critical for timely therapeutic administration. Quantitative real-time PCR provides a rapid, sensitive and specific tool for molecular i...
متن کاملAbsorption of orally administered nafcillin in normal healthy volunteers.
The absorption of orally administered nafcillin sodium monohydrate buffered with calcium carbonate was studied in 10 healthy human volunteers. Dosages of 500 mg and 1 g were studied in fasting and nonfasting states. There was considerable individual variation in the absorption of nafcillin, although measurable serum concentrations were obtained in all subjects. With few exceptions, peak serum c...
متن کاملNafcillin treatment of Staphylococcus aureus meningitis.
Serial serum and cerebrospinal fluid nafcillin concentrations were determined in a patient successfully treated with nafcillin (200 mg/kg per day) for Staphylococcus aureus bacteremia and meningitis. Nafcillin and methicillin cerebrospinal fluid concentrations were compared.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 16 2 شماره
صفحات -
تاریخ انتشار 1979