SU-E-T-526: Evaluation of Dose Mapping Errors via Use of a Volume-Based Dose Mapping Method.

نویسندگان

  • H Chen
  • N Saleh-Sayah
  • W Watkins
  • C Yan
  • F Salguero
  • E Heath
  • J Siebers
چکیده

PURPOSE To quantify dose mapping errors (DMEs) of a point-based dose mapping method for 4D lung treatment plans. METHODS Point-based dose mapping methods utilize deformation vector fields (DVFS) to interpolate dose from a deformed image. Volume-based dose mapping methods consider the volume overlap between deformed and reference voxels; defining dose as the integral energy divided by the integral mass of the voxel, and conserving integral dose . DME is defined as the dose differences between volume-based and point-based mapped dose (DME=(DpointBased-DvolumeBased)/DRx). The DME for a 4D lung case is compared with a bitmap DME method, both using a Pinnacle research version 8.1y DVF. DME is computed for ten 4D lung cases (five 10 phases, five 3 phase) with Pinnacle research version 9.100 DVFs. Multi-phase accumulated 4D DMEs are also evaluated. RESULTS For all cases, the largest DMEs are located in the dose/density gradient regions. With Pinnacle 8.1y DVF, mapping dose from phase 9 to phase 0, results in a DME=-0.2%±6.1% (range of -76%∼112%). The same case with Pinnacle 9.100 DVFs, DME=0.3%±4.8%(-41%∼32%). Locations of large DME are consistent with those from the bitmap method. For the ten 4D lung cases, accumulated mean DME are within ±0.07% (std. deviations: 1∼5%, range -102%∼64%). Maximum tumor DMEs are less than 30cGy (DRx=7200cGy) for all patients. CONCLUSIONS Due to its inherent integral dose conservation, volume-based dose mapping methods can quantify errors in point-based dose mapping methods. While mean DME values are small for the cases tested, standard deviations near 5% indicate that a substantial number of voxels have ∼5% dose mapping errors, however these dose errors do not occur in the target structures. Work supported by NIH P01CA116602.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

A GIS-based weights-of-evidence model for mineral potential mapping of hydrothermal gold deposits in Torbat-e-Heydarieh area

The method of weights of evidence is one of the most important data driven methods for mineral potential mapping in GIS. In this method, considering the characteristics of known mineralized locations, we can prospect new mineralized areas. In this research work, the method of weights of evidence has been used for hydrothermal gold potential mapping in Torbat-e-Heydarieh area, east of Iran. As a...

متن کامل

Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy

Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose m...

متن کامل

The use of concept mapping and Vee diagram to calculate the volume by the integral

The concept mapping and the Vee diagram are important tools for improving the level of conceptual learning of mathematics in all educational levels that can play an important role in the learner's achievement. The purpose of this study is to use a concept mapping and Vee diagram, to calculate the volume of an object by the integral, includes the reaction of what a teacher really knows, the way ...

متن کامل

The feasibility of direct treatment planning via contrast-enhanced computed tomography: an evaluation of dose differences based on the dimensional dose distribution comparison method

Background: We used a MapCHECK software-based dimensional dose distribution comparison method capable of evaluating point-to-point geometrical dose differences in volume to determine whether doses obtained from an enhanced computed tomography (CT)-based treatment plan, which better defines the target regions and organs at risk, differs from doses obtained from plain CT and then evaluated the fe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part18  شماره 

صفحات  -

تاریخ انتشار 2012