Potential aluminium(III)- and gallium(III)-selective optical sensors based on porphyrazines.

نویسندگان

  • Tomasz Goslinski
  • Ewa Tykarska
  • Michal Kryjewski
  • Tomasz Osmalek
  • Stanislaw Sobiak
  • Maria Gdaniec
  • Zbigniew Dutkiewicz
  • Jadwiga Mielcarek
چکیده

Porphyrazines possessing non-coordinating alkyl (propyl) and aralkyl (4-tert-butylphenyl) groups in the periphery were studied as optical sensors for a set of mono-, di- and trivalent cations. Investigated porphyrazines in the UV-Vis monitored titrations revealed significant responses towards aluminium and gallium cations, unlike other metal ions studied. Additionally, porphyrazine possessing 4-tert-butylphenyl peripheral substituents showed sensor property towards ruthenium cation and was chosen for further investigation. The presence of isosbestic points in absorption spectra for its titration with aluminium, gallium and ruthenium cations, accompanied by a linear Benesi-Hildebrand plot, proved complex formation. The continuous variation method was used to determine binding stoichiometry in 1:1 porphyrazine-metal ratio. X-Ray studies and density functional theory calculations were employed to investigate octa(4-tert-butylphenyl)porphyrazine structure. The results helped to explain the observed selectivity towards certain ions. Interaction between ion and porphyrazine meso nitrogen in a Lewis acid-Lewis base manner is proposed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Al(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore

A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M  with Nernstian slope of 19...

متن کامل

Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Synthesis and Crystal Structure of a Novel Six-Coordinate Gallium (III) Complex

The reaction of gallium (III) nitrate octahydrate with the proton transfer compound (pydaH2)2+ (pydc)2– ( where  pyda  is 2,6-pyridinediamine and pydcH2 is 2,6-pyridinedicarboxylic acid) leads to the formation of (C5H8N3) [Ga(C7H3NO4)2] · 4H2O · CH3OH. The crystal system of the anionic complex is triclinic with space group Pī and two molecules per unit cell. The unit cell parameters are a=10.23...

متن کامل

Simultaneous Second Order Derivative Spectrophotometric Determination Of Gallium (III) and Aluminium(III) using Diacetylmonoxime IsonicotinoylHydrazone

Diacetylmonoxime Isonicotinoyl Hydrazone is new chromogenic reagent for the simultaneous determination of Gallium (III) and Aluminium(III). The reagent gives greenish yellow color in sodium acetateacetic acid buffer medium with the metal ions. The maximum absorbance at 377 and 367 nm for Ga(III) and Al(III) respectively. The molar absorptivities of Al(III) and Ga(III) are 2.69 x 10 and 3.17 x 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2011