Multiple radiographic projections in detecting intra-articular screw penetration during fixation of femoral neck fractures.

نویسندگان

  • Lei Zhang
  • Guangmao Lin
  • Guojing Yang
  • Edem Prince Ghamor-Amegavi
  • Min Liu
  • Zhanpeng Pan
  • Shanxi Chen
چکیده

The authors performed a cadaveric study to evaluate the efficacy of multiple fluoroscopic projections in detecting intra-articular penetration of the screws during femoral neck fracture fixation and also to determine the most suitable radiographic projection. Models of intra-articular penetration in 8 normal proximal femur specimens were created by placing the pins in different quadrants of the femoral head and extending 1 mm beyond the femoral head surface. The tip-to-surface distance was measured on anteroposterior (AP) and lateral views, with the femur positioned at varying degrees of rotation, flexion, adduction, and abduction. After correcting for differences in magnification, associations between the tip-to-surface distance and femur position were noted. In certain femur positions and K-wire placements, conventional AP and lateral views did not show that the wire extended beyond the surface of the femoral head. The tip-to-surface distance on an AP radiograph with the femur in the neutral position was not comparable to that on the lateral view with the femur positioned at 20° of adduction (P=.821). However, the tip-to-surface distance on an AP radiograph with the femur in the neutral position varied significantly (P<.001) from all other tip-to-surface distances on either the AP or lateral projection. A linear association was found between the tip-to-surface distance and femur rotation angles on AP views and between femur adduction and abduction angles on lateral views. In conclusion, fluoroscopy in varied projections at different angles can detect unrecognized intra-articular screw penetration during internal fixation of femoral neck fracture. Additional special projection methods are suggested to identify and prevent intra-articular screw penetration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

Articular penetration is more likely in Garden-I fractures of the hip.

Plain radiographs show only two dimensions of a three-dimensional object. On anteroposterior and lateral radiographs an implant may appear to be safely within the head of the femur although surface penetration has occurred. We have attempted to identify this complication in the treatment of fractures of the femoral neck and have analysed the position of a screw or pin in the femoral head and ne...

متن کامل

Proximal Femoral Nail - A Minimally Invasive Method for Stabilization of Pertrochanteric and Subtrochanteric Femoral Fractures

Fractures of the proximal femur are a big challenge in traumatology. Rapid strides in implant and instrumentations in quest of ideal fixation of pertrochanteric and subtrochanteric femoral fractures have made various options available like Fixed-angled nail plate, Screw plates, Angled blade plate, Dynamic Hip Screw etc. The present study aims to study the role of standard PFN as a minimal invas...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 10  شماره 

صفحات  -

تاریخ انتشار 2014