New Assignment of Mass Values and Uncertainties to NIST Working Standards

نویسنده

  • Richard S. Davis
چکیده

For some time it had been suspected that values assigned to NIST working standards of mass were some 0.17 mg/kg larger than mass values based on artifacts representing mass in the International System of Units (SI). This relatively small offset, now confirmed, has had minimal scientific or technological significance. The discrepancy was removed on January 1, 1990. We document the history of the discrepancy, the studies which allow its removal, and the methods in place to limit its effect and prevent its recurrence. For routine calibrations, we believe that our working standards now have a long-term stability of 0.033 mg/kg (3σ) with respect to the national prototype kilograms of the United States. We provisionally admit an additional uncertainty of 0.09 mg/kg (3σ), systematic to all NIST mass measurements, which represents the possible offset of our primary standards from standards maintained by the Bureau International des Poids et Mesures (BIPM). This systematic uncertainty may be significantly reduced after analysis of results from the 3rd verification of national prototype kilograms, which is now underway.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NIST Measurement Service for DC Standard Resistors

At the National Institute of Standards and Technology (NIST), the U.S. representation of the ohm is based on the quantum Hall effect, and it is maintained and disseminated at various resistance levels by working reference groups of standards. This document describes the measurement systems and procedures used to calibrate standard resistors and current shunts of nominal decade values in the res...

متن کامل

Uncertainty Propagation for NIST Visible Spectral Standards

Uncertainties in the NIST spectral standards for detectors and sources in the visible wavelength range are propagated from the high accuracy cryogenic radiometer measurements, taking correlations into account at every stage. Partial correlations between spectral values at different wavelengths, important for subsequent radiometric calculations, are estimated. Uncertainty propagation through fit...

متن کامل

Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.

An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadr...

متن کامل

New Measurement Service for Determining Pressure Sensitivity of Type LS2aP Microphones by the Reciprocity Method

A new National Institute of Standards and Technology (NIST) measurement service has been developed for determining the pressure sensitivities of American National Standards Institute and International Electrotechnical Commission type LS2aP laboratory standard microphones over the frequency range 31.5 Hz to 20 000 Hz. At most frequencies common to the new service and the old service, the values ...

متن کامل

Calibration of dissipation factor standards

Working standards for dissipation factor (D) obtained by connecting a shielded three-tenninal capacitor in series with a shielded precision resistor have been developed for calibration purposes. Precision conductance boxes have been built for use with a single three-tenninallOOO pF gas capacitor standard to create dissipation factor standards having values from 2 x 10-5 to 1 X 10-2. The design ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 1990