Resolution scaling in STED microscopy.
نویسندگان
چکیده
We undertake a comprehensive study of the inverse square root dependence of spatial resolution on the saturation factor in stimulated emission depletion (STED) microscopy and generalize it to account for various focal depletion patterns. We used an experimental platform featuring a high quality depletion pattern which results in operation close to the optimal optical performance. Its superior image brightness and uniform effective resolution <25 nm are evidenced by imaging both isolated and self-organized convectively assembled fluorescent beads. For relevant saturation values, the generalized square-root law is shown to predict the practical resolution with high accuracy.
منابع مشابه
Defining the Noise-limited-resolution for Stimulated Emission Depletion Microscopy
With recent developments in microscopy, such as stimulated emission deletion (STED) microscopy, far-field imaging at resolutions better than the diffraction limit is now a commercially available technique. Here, we analyse how the interplay between shot noise, thermal noise, the saturation intensity of a fluorescent label, and the damage threshold of the sample changes the maximum resolution of...
متن کاملTime-gating improves the spatial resolution of STED microscopy.
Stimulated-emission depletion (STED) microscopy improves image resolution by encoding additional spatial information in a second stimulated-decay channel with a spatially-varying strength. Here we demonstrate that spatial information is also encoded in the fluorophore lifetime and that this information can be used to improve the spatial resolution of STED microscopy. By solving a kinetic model ...
متن کاملDevelopment of 3d Super- Resolution Tomographic Sted Microscopy and Its Application to Studies on Bone Resorption
In this doctoral thesis, a tomographic STED microscopy technique for 3D super-resolution imaging was developed and utilized to observe bone remodeling processes. To improve upon existing methods, we have used a tomographic approach using a commercially available stimulated emission depletion (STED) microscope. A certain region of interest (ROI) was observed at two oblique angles: one at a stand...
متن کاملSTED Super-Resolution Microscopy of Clinical Paraffin-Embedded Human Rectal Cancer Tissue
Formalin fixed and paraffin-embedded human tissue resected during cancer surgery is indispensable for diagnostic and therapeutic purposes and represents a vast and largely unexploited resource for research. Optical microscopy of such specimen is curtailed by the diffraction-limited resolution of conventional optical microscopy. To overcome this limitation, we used STED super-resolution microsco...
متن کاملNanoparticle-Assisted STED Nanoscopy with Gold Nanospheres
We demonstrate stimulated emission depletion (STED) microscopy with 20 nm gold nanospheres coated by fluorescently doped silica. We demonstrate significantly improved spatial resolution down to 75 nm, which is the first time that hybrid NPs are used in STED imaging beyond the diffraction limit of confocal microscopy. Unlike previous demonstrations of super-resolution with metal nanoparticles wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2008