Automatic calibration for on-line process monitoring in continuous-flow systems

نویسندگان

  • Manuel Agudo
  • Angel Ríos
  • Miguel Valcárcel
  • Andrei Danet
چکیده

An automatic procedure for calibration in continuous-flow systems is proposed. A flow gradient unit in the sample channel, controlled via a switching valve, delivers a concentration gradient of the standard so that the standard concentration varies with time after the flow-rate gradient is started. Thus, the signal (absorbance)- concentration relationship can be determined and checked for (recalibration) as frequently as required. The procedure was applied to a simulated continuous monitoring of hydrazine in waters, as well as to specific water samples that were spiked with hydrazine at different concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration in process monitoring by using unsegmented continuous-flow systems

An overview is presented of the different aspects of the role of analytical chemistry in process monitoring and control. On-line monitoring is currently the most attractive option in this area, especially with unsegmented-flow techniques. In addition to allowing automation of these systems, the variety of ways in which calibration and recalibration can be performed allows their adaptation to an...

متن کامل

OPTIMIZATION-BASED MONITORING-SUPPORTED CALIBRATION OF A THERMAL PERFORMANCE SIMULATION MODEL

Building performance simulation is being increasingly deployed beyond the building design phase to support efficient building operation. Specifically, the predictive feature of the simulation-assisted building systems control strategy provides distinct advantages in view of building systems with high latency and inertia. Such advantages can be exploited only if model predictions can be relied u...

متن کامل

Implementation of On-Line Monitoring to Increase the Calibration Interval of Pressure Transmitters

Typically, the calibration of an instrument such as a pressure transmitter involves two steps as follows: Determine if calibration is needed. This step is performed by providing the instrument with a series of known inputs covering the operating range of the instrument. The output of the instrument is recorded for each input and compared with the acceptance criteria for the instrument. Calibrat...

متن کامل

State of the art in on-line techniques coupled to flow injection analysis FIA/on-line- a critical review

Flow injection analysis (FIA) has emerged as an increasingly used laboratory tool in chemical analysis. Employment of the technique for on-line sample treatment and on-line measurement in chemical process control is a growing trend. This article reviews the recent applications of FlA. Most papers refer to on-line sample treatment. Although FIA is very well suited to continuous on-line process m...

متن کامل

On-Line Measurement of Dissolved Methane Concentration During Methane Fermentation in a Loop Bioreactor

A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 17  شماره 

صفحات  -

تاریخ انتشار 1995