An Improved Micro-power Pre-amplifier for Dry-electrode ECG Recording

نویسندگان

  • Martin J. Burke
  • Cedric Assambo
چکیده

This paper describes the development of a very low-power pre-amplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100μV 10mV from a lead II electrode configuration. The amplifier provides a gain of 42dB in a 3dB bandwidth of 0.05Hz 2kHz with an input impedance of 280MΩ and a CMRR of greater than 80dB. Its gain and phase characteristics meet the recommendations of the AHA, making it suitable for clinical diagnostic monitoring. The amplifier has a power consumption of 20μW operating from a 3V battery and is intended for use in small, lightweight, portable electrocardiographic equipment and heart-rate monitoring instrumentation. Key-Words: ECG, Dry-electrodes, Ultra-low power amplifier, Skin-Electrode Interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Domain Response of ECG Bioelectric Amplifiers

This paper investigates the low-frequency response of a multi-stage bioelectric amplifier intended for use in the measurement of the electrocardiogram (ECG) using dry contact electrodes. These electrodes have an impedance which is typically an order of magnitude greater than that of the standard disposable self-adhesive electrodes used in clinical ECG recording. The design was undertaken with t...

متن کامل

An ultra-high input impedance ECG amplifier for long-term monitoring of athletes

We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was compared with a clinically approved ECG...

متن کامل

Electrical Characterisation of Dry Electrodes for ECG Recording

This paper reports the measurement of the properties of dry or pasteless conductive electrodes to be used for long-term recording of the human electrocardiogram (ECG). Knowledge of these properties is essential for the correct design of the input stage of associated recording amplifiers. Measurements were made on seven commercially available conductive carbon based electrodes at pressures of 5m...

متن کامل

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on...

متن کامل

Interference Reduction in Ecg Recordings by Using a Dual Ground Electrode

− Power distribution lines are a major source of interference in ECG recordings obtained with surface electrodes. Displacement currents coupled to electrodes, their leads and directly into the body, and stray capacitance in power supply transformers, result into differential-mode, common-mode and isolation-mode interference. Shielding electrode leads reduces displacement currents coupled to the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007