A diagnostic pitfall in a patient with an implantable cardioverter-defibrillator.
نویسندگان
چکیده
Apatient with dilated cardiomyopathy and aborted sudden death was admitted for repeated shocks from his Guidant Ventak Prizm dual chamber implantable cardioverterdefibrillator (ICD). Interrogation of stored events over the last six months revealed 46 episodes at a rate of 140/min, interpreted as ventricular tachycardia (VT). These were usually interrupted by programmed overdrive ventricular pacing, but sometimes required shocks. During monitoring, rhythm strips showed repeated episodes of narrow complex tachycardia at 136/min, initiated by an atrial premature beat (APB) with a prolonged PR interval (*), without visible P waves during tachycardia (A). These episodes set off antitachycardia ventricular pacing by the ICD with return to sinus rhythm (B). Interrogation of stored events of the ICD revealed similar episodes initiated by an APB (+), with inconsistent atrial sensing during tachycardia (AS 2033), despite evident 1:1 atrial activity on the electrogram. This was due to the very short ventriculoatrial (VA) interval, with atrial activity falling within the blanking period of 85 ms (during which the atrial channel is “blinded” to avoid far-field sensing of ventricular activity). Thus apparent atrioventricular (AV) dissociation led to misdiagnosis of VT by the device. AV nodal re-entrant tachycardia was suspected and subsequently confirmed by an electrophysiological study, leading to successful catheter radiofrequency ablation of the slow pathway. At eight months’ follow up, interrogation of the ICD showed no relapse of tachycardia. This case illustrates how ICDs may be tricked by a relatively common supraventricular arrhythmia despite dual chamber technology, resulting in inappropriate shocks.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملزندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیدهشناسی
Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملتأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)
Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients . Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 89 4 شماره
صفحات -
تاریخ انتشار 2003