Comparison between the SBF response of hydroxyapatite coatings deposited using both a plasma-spray and a novel co-incident micro-blasting technique J.N.Barry, D.P.Dowling
نویسندگان
چکیده
This paper reports on the response of hydroxyapatite (HA) coatings, fabricated using two deposition technologies, to immersion in simulated body fluid (SBF). The deposition methods used were: plasma spray, a commercial standard, and CoBlast, a novel low temperature microblast technique. In the case of the latter, HA coatings are deposited by simultaneous blasting HA and abrasive powders concentrically at a metallic substrate, resulting in a thin layer of HA (approx. 2.5 μm thick). Groups of the CoBlast and plasma spray HA coatings were immersed in 7 ml of SBF solution for 1, 2, 4, 7, 14 and 28 days, and were subsequently removed and examined for any alterations caused by the SBF solution. It was noted from this study that the CoBlast HA coatings appeared to undergo a two step calcium phosphate recrystallisation process; initial homogenous nucleation and subsequent heterogeneous nucleation. Conversely recrystallisation on the plasma spray coatings appeared to proceed largely through a heterogeneous nucleation process. Two factors that may influence the differences in HA recrystallisation is the presence of amorphous HA resulting in rapid dissolution, and/or the significantly lower surface area (roughness) offered to the SBF solution by the CoBlast coatings. The interpretation of recrystallisation mechanisms from this preliminary study is limited however by the differences in coating morphology and thickness (27 versus 2 μm) for the plasma spray and CoBlast HA coatings respectively.
منابع مشابه
Role of Post Heat Treatment of Plasma Sprayed Pure and Al2O3-TiO2 Reinforced Hydroxyapatite Coating on the Microstructure and Mechanical Properties
Pure and 10 wt% 80Al2O3-20TiO2 reinforced hydroxyapatite coatings were successfully deposited on Ti6Al4V substrate by plasma spray technique for bio medical applications. Post coating heat treatment was carried out to study the effect of heat treatment on improvement in micro structure and mechanical properties of coatings. Coating was characterized by SEM/EDAX and XRD analysis. Positive impact...
متن کاملBio-ceramic Composite Coatings by Cold Spray Technology
Bioceramics such as hydroxyapatite (HAP) have been conventionally deposited by plasma spray technique. However, due to the inherent high temperature in the plasma, deleterious effects such as evaporation, phase alteration, residual stress, debonding, and gas release etc., commonly occur in these coatings. This paper presents a novel approach to deposit bioceramic coatings at temperatures well b...
متن کاملInfluence of substrate metal alloy type on the properties of hydroxyapatite coatings deposited using a novel ambient temperature deposition technique.
Hydroxyapatite (HA) coatings are applied widely to enhance the level of osteointegration onto orthopedic implants. Atmospheric plasma spray (APS) is typically used for the deposition of these coatings; however, HA crystalline changes regularly occur during this high-thermal process. This article reports on the evaluation of a novel low-temperature (<47°C) HA deposition technique, called CoBlast...
متن کاملAnalytically Modeling of In Vitro Calcium Dissolution of Plasma- Sprayed Hydroxyapatite Coatings
The in vitro dissolution of plasma-sprayed hydroxyapatite (PHA) coatings with different characteristics, produced by various spraying conditions, in a Tris-buffered solution at pH 7.4 was experimentally studied through the measurement of calcium ions release with Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and then modeled. Three coating characteristics, th...
متن کاملTHE EFFECTS OF PLASMA SPRAY PARAMETERS ON THE MICROSTRUCTURE AND PHASE COMPOSITION OF THERMAL BARRIER COATINGS MADE BY SPPS PROCESS
In this paper the effect of plasma spray parameters, atomizing gas and substrate preheat temperature on microstructure and phase composition of YSZ coatings produced by SPPS process have been investigated. The experimental results showed that increasing the power of plasma, using hydrogen as the precursor atomizing gas and increasing substrate preheat temperature decrease the amount of non-pyro...
متن کامل