Vital role of volume and number of needles in HDR brachytherapy (HDR-BT) of prostate cancer

نویسندگان

  • Adam Chicheł
  • Marek Kanikowski
  • Janusz Skowronek
چکیده

PURPOSE The quality of HDR-BT of prostate cancer depends on operator skills, anatomy, prostate volume and relation to surrounding tissues as well as previous diseases and treatments of a patient. There is a rare data available concerning the minimum number of needles and its influence on dose distribution, side effects and long-term outcome. The study is to determine the minimal prostate volume and minimum number of needles suitable for HDR-BT in order to obtain an implant of good quality. MATERIAL AND METHODS 181 patients with localized prostate cancer were treated with interstitial HDR-BT boost. 15 Gy from HDR-BT was administered after 50 Gy from EBRT. Clinical, volumetric and dosimetric data were collected. Treatment plans were divided into Group A, consisted of optimal treatment plans (P-D90 > 90%, P-V200 < 15%, U-D10 < 125%, U-Dmax < 160%, R-D10 < 85%) and Group B, with suboptimal plans. RESULTS The difference between two groups was statistically significant (p = 0.013) with regard to number of needles. There was no statistically significant difference concerning prostatic volume. Median number of inserted needles in the first and the second group resulted in 15 (range 9-18) and 13 (range 8-18), respectively. Differences were the most eminent in patients with prostate glands of small volume (< 20 cc). In the study, either the minimum number of needles nor minimal prostate gland volume were not clearly defined in terms of high probability of achieving a good quality implant. CONCLUSIONS Larger volume and higher number of needles are related to an advanced probability of treatment plan with all DVC fulfilled. The minimum number of needles suggested is > 9, optimally ≥ 13. Furthermore, the minimal prostate volume recommended is > 12 cc, optimally ≥ 18 cc. The volume of insufficient size and/or small number of needles results in suboptimal treatment plans.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between treatment plan parameters and particular prognostic factors in prostate cancer treated with high–dose–rate brachytherapy (HDR–BT) as a boost

PURPOSE Certain constraints for target coverage and dose limits in Organs at Risk (OARs) shows some evidence that doses values and homogeneity index in treated volume depends on prognostic factors such as prostate volume, location of urethra and the number of inserted applicators. Our study is to determine the relation between values of the doses in prostate, OARs and particular prognostic fact...

متن کامل

Cosmetic effect in patients with early breast cancer treated with breast conserving therapy (BCT) and with HDR brachytherapy (HDR-BT) “boost”

PURPOSE The estimation of cosmetic effect in 93 patients with early breast cancer treated with breast conserving surgery (BCS) followed by combined radiotherapy, including HDR brachytherapy (HDR-BT) boost. MATERIAL AND METHODS After BCS (tumorectomy or quadrantectomy) external beam radiation therapy (EBRT) was used in total dose of 50 Gy for the whole breast. Tumor bed was localized basing on...

متن کامل

The use of nomograms in LDR-HDR prostate brachytherapy

PURPOSE The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LD...

متن کامل

Dosimetry analyses comparing high-dose-rate brachytherapy, administered as monotherapy for localized prostate cancer, with stereotactic body radiation therapy simulated using CyberKnife

The purpose of this study was to perform dosimetry analyses comparing high-dose-rate brachytherapy (HDR-BT) with simulated stereotactic body radiotherapy (SBRT). We selected six consecutive patients treated with HDR-BT monotherapy in 2010, and a CyberKnife SBRT plan was simulated for each patient using computed tomography images and the contouring set used in the HDR-BT plan for the actual trea...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009