New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
نویسندگان
چکیده
The pneumotachometer is currently the most accepted device to measure tidal breathing, however, it requires the use of a mouthpiece and thus alteration of spontaneous ventilation is implied. Respiratory inductive plethysmography (RIP), which includes two belts, one thoracic and one abdominal, is able to determine spontaneous tidal breathing without the use of a facemask or mouthpiece, however, there are a number of as yet unresolved issues. In this study we aimed to describe and validate a new RIP method, relying on a combination of thoracic RIP and nasal pressure signals taking into account that exercise-induced body movements can easily contaminate RIP thoracic signals by generating tissue motion artifacts. A custom-made time domain algorithm that relies on the elimination of low amplitude artifacts was applied to the raw thoracic RIP signal. Determining this tidal ventilation allowed comparisons between the RIP signal and simultaneously-recorded airflow signals from a calibrated pneumotachometer (PT). We assessed 206 comparisons from 30 volunteers who were asked to breathe spontaneously at rest and during walking on the spot. Comparisons between RIP signals processed by our algorithm and PT showed highly significant correlations for tidal volume (Vt), inspiratory (Ti) and expiratory times (Te). Moreover, bias calculated using the Bland and Altman method were reasonably low for Vt and Ti (0.04 L and 0.02 s, respectively), and acceptable for Te (<0.1 s) and the intercept from regression relationships (0.01 L, 0.06 s, 0.17 s respectively). The Ti/Ttot and Vt/Ti ratios obtained with the two methods were also statistically correlated. We conclude that our methodology (filtering by our algorithm and calibrating with our calibration procedure) for thoracic RIP renders this technique sufficiently accurate to evaluate tidal ventilation variation at rest and during mild to moderate physical activity.
منابع مشابه
Inductive plethysmography potential as a surrogate for ventilatory measurements during rest and moderate physical exercise
BACKGROUND Portable respiratory inductive plethysmography (RIP) systems have been validated for ventilatory assessment during resting conditions and during incremental treadmill exercise. However, in clinical settings and during field-based exercise, intensity is usually constant and submaximal. A demonstration of the ability of RIP to detect respiratory measurements accurately during constant ...
متن کاملRespiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.
BACKGROUND Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor f...
متن کاملBody Mass Index-Dependent Ventilatory Parameters From Respiratory Inductive Plethysmography During 6-Minute Walk Test.
BACKGROUND Walking is part of obesity management. Assessment of ventilatory impairments and consequences for gait induced by obesity could be clinically helpful. We aimed to develop a method to accurately monitor ventilation with respiratory inductive plethysmography (RIP) in subjects with high body mass indices (BMIs) during a 6-min walk test (6MWT). METHODS 25 volunteers were divided into 2...
متن کاملValidation of respiratory inductive plethysmography in patients with pulmonary disease.
The assumption that the respiratory system behaves with 2 df of motion in healthy persons allows calibration of respiratory inductive plethysmography (RIP) with spirometry (SP). To ascertain whether RIP could be calibrated by the same assumption in patients with lung disease, even though at least 3 df of motion are visualized (ie, upper and lower rib cage and upper and lower abdomen move out of...
متن کاملA Wearable Technology Revisited for Cardio-Respiratory Functional Exploration: Stroke Volume Estimation from Respiratory Inductive Plethysmography
The objective of the present study is to extract new information from complex signals generated by Respiratory Inductive Plethysmography (RIP). This indirect cardio-respiratory (CR) measure is a well-known wearable solution. We applied time-scale analysis to estimate cardiac activity from thoracic volume variations, witnesses of CR interactions. Calibrated RIP signals gathered from 4 healthy vo...