Prevention of airway fires: do not overlook the expired oxygen concentration.

نویسندگان

  • Matthew Remz
  • Isaac Luria
  • Michael Gravenstein
  • Scott D Rice
  • Timothy E Morey
  • Nikolaus Gravenstein
  • Mark J Rice
چکیده

BACKGROUND It is generally accepted that when an ignition source is used the inspired oxygen concentration (FIO2) should be <30% in the breathing circuit to help prevent airway fires. The time and conditions required to reduce a high O2% in the breathing circuit to <30% has not yet been systematically studied. METHODS We evaluated the inspired and expired circuit oxygen concentration response times of an Aestiva Avance S/5 anesthesia machine to reach an FIO2 of <30% from a starting FIO2 of 100% and 60% after reducing the FIO2 to 21%. The circuit was connected to a human patient simulator which has a functional residual capacity of 2 L, total lung capacity of 2.8 L, an oxygen consumption of 200 mL/min, and respiratory quotient of 0.8. Fresh gas flow (FGF) inputs of 2 L/min and 5 L/min were chosen to represent a spectrum of typical clinical FGF rates. Minute ventilation was set at 4 L/min. Determining the requisite median time to reach an O2 concentration of <30% in the breathing circuit was the primary aim of the study. RESULTS The median times (1st-99th percent confidence interval) required to achieve inspiratory and expiratory oxygen concentrations of <30% with the extended circuit configuration when starting at 60% for 5 L FGFs were 35 (32-36) and 104 (88-122) seconds, respectively. With 2 L FGF, these median times increased to 303 (291-313) and 255 (232-278) seconds, respectively. A shortened circuit configuration (P = 0.006) and higher FGF flow rate (P < 0.0001) were noted to be factors decreasing the median time required to achieve an oxygen concentration of <30%. CONCLUSIONS Both inspired and expired circuit oxygen concentration may take minutes to decrease to <30% depending on circuit length, FGF rate, and starting circuit oxygen concentration. During the reduction in FIO2, the expiratory oxygen concentration may be >30% for a considerable time after the FIO2 is in a "safe" range. An increased expired oxygen concentration should also be considered an airway fire risk, and patient care protocols may need to be modified based on future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased hydrogen peroxide and thiobarbituric acid-reactive products in expired breath condensate of asthmatic patients.

Symptoms of bronchial asthma are a manifestation of airway inflammation. Circulatory leucocytes (predominantly eosinophils, mast cells and neutrophils), release inflammatory mediators, including reactive oxygen species, i.e. superoxide anion which is dismutated to hydrogen peroxide (H2O2). Neutrophils from asthmatics generate greater amounts of these species than those of healthy subjects. Some...

متن کامل

The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP)

BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on tr...

متن کامل

Effect of Dissolved Oxygen and Chemical Oxygen Demand to Nitrogen Ratios on the Partial Nitrification/Denitrification Process in Moving bed Biofilm Reactors

Partial nitrification was reported to be technically feasible and economically favorable, especially for wastewaterwith high ammonium concentration or low C/N ratio. In this study, the effect of dissolved oxygen (DO)and influent ratio of chemical oxygen demand to nitrogen (COD/N) ratio on biological nitrogen removal fromsynthetic wastewater was investigated. Experiments were c...

متن کامل

Application of Gene Expression Programming to water dissolved oxygen concentration prediction

This research based on record and collected data from four stations at Eymir Lake, Turkey, which are monitored daily in seven months. Water quality monitoring using former methods are time-needed and expensive, while the application of gene expression programming is more understandable, rapid, and reliable which is used in this article to provide a prediction for dissolved oxygen. The concentra...

متن کامل

Isolation, identification and characterization of thermo-tolerant acetic acid bacteria for semi-continuous acetous fermentation at high temperature

Nowadays, vinegar is industrially produced by mesophilic acetic acid bacteria (AAB). However, temperature fluctuation during acetous fermentation is inevitable, and may cause process disturbances. This can be mostly avoided using thermo-tolerant AAB. The main purpose of the present study was to isolate thermo-tolerant AAB. Fermentation performances were then evaluated. Twenty-eight different is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 117 5  شماره 

صفحات  -

تاریخ انتشار 2013