The effect of tibial curvature and fibular loading on the tibia index.
نویسندگان
چکیده
The tibia index (TI) is commonly used to predict leg injury based on measurements taken by an anthropomorphic test device (ATD). The TI consists of an interaction formula that combines axial loading and bending plus a supplemental compressive force criterion. Current ATD lower limbs lack geometric biofidelity with regard to tibial curvature and fibular load-sharing. Due to differences in tibial curvature, the midshaft moments induced by axial loading are different in humans and ATDs. Midshaft tibial loading in the human is also reduced by load-sharing through the fibula, which is not replicated in current ATDs. In this study, tibial curvature and fibular load-sharing are quantified through CT imaging and biomechanical testing, and equations are presented to correct ATD measurements to reflect the loading that would be experienced by a human tibia.
منابع مشابه
Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملHindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?
Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated f...
متن کاملCorrelation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants
of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...
متن کاملThe effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
OBJECTIVE To compare the fixation stability of intramedullary nails to that of locked plates for the treatment of distal metaphyseal tibia and fibula fractures. METHODS A simulated, distal metaphyseal tibia fracture was created in 8 pairs of cadaveric tibia-fibula specimens. One of each pair was treated using an intramedullary nail (Trigen IM Nail System; SN Richards, Memphis, TN) and the oth...
متن کاملThe anatomical safe zone for medial opening oblique wedge high tibial osteotomy.
INTRODUCTION The end of medial opening oblique wedge high tibial osteotomy (HTO) points into a narrow area between the articular cartilage of the posterolateral proximal tibia and proximal tibiofibular joint (PTFJ) at the tibial site, which is an anatomical safe zone (ASZ) for osteotomy. We studied the ASZ and its relation to the fibular tip, including the level of posterior cruciate ligament (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Traffic injury prevention
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2004