Kinetics of enzymatic O-methylation: its value in assays for catecholamines in plasma.
نویسندگان
چکیده
The kinetics of enzymatic O-methylation of catecholamines were studied under conditions like those used in the radioenzymatic assay of plasma catecholamines. Inappropriate Michaelis-Menten kinetics and linear approximations of exponential equations were not used. Mathematical analysis indicated the importance of the ratio of methyl donor (S-adenosylmethionine) to substrate (catecholamine) concentration. If the reaction is incomplete, only a large ratio will allow linear approximations between product formed and initial catecholamine concentration. The use of high-concentration internal standards to correct for plasma interference may give erroneous results by reducing this ratio. Accuracy will be improved by ensuring (a) that S-adenosylmethionine is always greatly in excess of catecholamine, (b) that concentrations of added standards are of the same order as for endogenous catecholamine, and (c) that a high activity of enzyme is used, to allow the reaction to reach completion even in the presence of some inhibition.
منابع مشابه
A convenient method to generate methylated and un-methylated control DNA in methylation studies
Methylated and un-methylated control DNA is an important part of DNA methylation studies. Although human and mouse DNA methylation control sets are commercially available, in case of methylation studies on other species such as animals, plants, and bacteria, control sets need to be prepared. In this paper a simple method of generating methylated and un-methylated control DNA is described. Whole...
متن کاملO-11: N-a-acetyltransferase 10 Protein Regulates DNA Methylation and Embryonic Development
Background Genomic imprinting is a heritable and developmentally essential phenomenon by which gene expression occurs in an allele-specific manner1. While the imprinted alleles are primarily silenced by DNA methylation, it remains largely unknown how methylation is targeted to imprinting control region (ICR), also called differentially methylated region (DMR), and maintained. Here we show that ...
متن کاملNovel double-isotope technique for enzymatic assay of catecholamines, permitting high precision, sensitivity and plasma sample capacity.
1. A novel use of a double-isotope method is described which allows radioenzymatic assays to combine precision and sensitivity. 2. In the catechol O-methyltransferase assay separate portions of each plasma sample are incubated with either S-[3H]- or S-[14C]-adenosyl-L-methionine. Standards of noradrenaline and adrenaline are added to the latter portions and are thus converted into standards of ...
متن کاملPlasma and Urine Catecholamines, Metabolic Enzymes, and Chromogranin-A
Background. Because acute exercise increases systemic catecholamines, we sought to determine whether exercise training would alter daily or exercise-related catecholamine release and inactivation. Methods and Results. In 24-hour urine collections, catecholamines and metabolites provided indexes of overall oxidative deamination, sulfation, and O-methylation. Plasma catecholamines, the sulfoconju...
متن کاملCatecholamine metabolic pathways and exercise training. Plasma and urine catecholamines, metabolic enzymes, and chromogranin-A.
BACKGROUND Because acute exercise increases systemic catecholamines, we sought to determine whether exercise training would alter daily or exercise-related catecholamine release and inactivation. METHODS AND RESULTS In 24-hour urine collections, catecholamines and metabolites provided indexes of overall oxidative deamination, sulfation, and O-methylation. Plasma catecholamines, the sulfoconju...
متن کاملذخیره در منابع من