Reversibility of albuminuria and continuous positive airway pressure compliance in patients of obstructive sleep apnea syndrome
نویسندگان
چکیده
A positive correlation between albuminuria and severity of obstructive sleep apnea syndrome (OSAS) has been demonstrated, as indexed by urine albumin-to-creatinine ratios (UACRs). However, the effect of continuous positive airway pressure (CPAP) treatment on albuminuria in OSAS patients has not been established.Sixty subjects, with apnea-hypopnea indices >15 events per hour and no other diagnoses associated with albuminuria, underwent overnight polysomnography for sleep apnea and were examined for UACR at baseline and after 6 months of CPAP therapy. CPAP compliance rates were also recorded.Significant improvement in UACR was found in OSAS patients with good compliance to CPAP treatment after 6 months of therapy (baseline vs 6-month follow-up, 32.0 ± 9.5 vs 19.2 ± 6.5 mg/g, respectively, P = 0.007), whereas slight worsening in UACRs was noted in patients with poor compliance to CPAP treatment (baseline vs 6-month follow-up, respectively, 16.7 ± 4.4 vs 19.1 ± 6.3 mg/g, respectively, P = 0.39). Change in UACR was significant between poor compliance versus good compliance groups (2.4 ± 2.7 vs -12.8 ± 4.4 mg/g, respectively, t = 2.9, P = 0.005). A significant correlation between improvement in UACR and CPAP compliance rates was also noted (Spearman's correlation coefficient: -0.37, P = 0.007). Baseline UACR, good CPAP compliance, and body mass index were independent predictors of changes in UACR.Adequate CPAP treatment improves albuminuria in OSAS patients. In addition to monitoring CPAP adherence and subjective sleepiness, UACR may offer an objective physiological index of CPAP therapeutic effectiveness.
منابع مشابه
Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach
Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...
متن کاملAlternatives for OSAHS treatment: selection of patients for upper airway surgery and oral appliances
Although continuous positive airway pressure (CPAP) is considered to represent the standard treatment for patients with moderate-to-severe obstructive sleep apnoea/hypopnoea syndrome (OSAHS), poor treatment compliance and/or refusal is an issue in ,20–30% of these
متن کاملThe importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.
INTRODUCTION Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance ...
متن کاملInterventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.
STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...
متن کاملObjective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.
Compliance with nasal continuous positive airway pressure (CPAP) has become a major concern, since this treatment is efficacious, but constraining. In 46 consecutive obstructive sleep apnoea (OSA) patients, we measured compliance with nasal CPAP by establishing a mean rate of use, with a built-in time counter read at three-month intervals, over a mean follow-up period of 232 +/- 27 days. The me...
متن کامل