Rare central venous catheter malposition – an ultrasound-guided approach would be helpful: a case report

نویسندگان

  • Keisuke Kumada
  • Nobuo Murakami
  • Hideshi Okada
  • Izumi Toyoda
  • Shinji Ogura
  • Hiroshi Kondo
  • Atsuhiro Fukuda
چکیده

BACKGROUND A central venous catheter enables the measurement of hemodynamic variations, such as accurate central venous pressure; catheter malposition may induce potentially fatal complications. This case report describes a rare central venous catheter tip malposition in the right internal mammary artery. CASE PRESENTATION A 56-year-old Japanese woman who presented with severe pneumonia secondary to scleroderma was treated under ventilator support because of acute respiratory failure. A right central venous catheter was inserted using a landmark technique to monitor central venous pressure and administer medications. However, central venous waveforms detected by the catheter using a pressure lot transducer were later found to be absent. Further imaging studies, including plain radiography, computed tomography, and angiography, confirmed central venous catheter malposition in the internal mammary artery. Her right internal mammary artery was embolized using two interlocking detachable coils, and the central venous catheter was removed from her internal mammary artery without further complications. CONCLUSIONS Internal mammary artery malposition is a rare but potentially lethal complication of central venous catheter catheterization; however, caution should be taken regarding the assessment of risk factors and management of a severe complication. An ultrasound-guided approach would be helpful.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال

Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...

متن کامل

Ultrasound-guided catheterization of the left subclavian vein without recognition of persistent left superior vena cava

RATIONALE A persistent left superior vena cava (PLSVC) is rare, but the most common thoracic venous anomaly. We report a case of PLSVC unrecognized during left subclavian vein catheterization using real-time ultrasound-guided supraclavicular approach. PATIENT CONCERNS A 79-year-old man with history of hypertension presented with traumatic subdural hemorrhage, subarachnoid hemorrhage, and epid...

متن کامل

Accidental Placement of Central Venous Catheter into Internal Mammary Vein: A Rare Catheter Malposition

477 The Editor, Central venous catheterization plays important roles in cardiac surgery. Although a relatively safe procedure, it is associated with multiple complications. Malposition of the catheter tip is one of them. This report presents a rare malposition of a catheter into left internal mammary vein (IMV). It also emphasizes the need for routine use of ultrasound to minimize such complica...

متن کامل

Correction of malposition of central venous catheter with 9-Fr introducer sheath assisted by mobile type diagnostic X-ray apparatus: a case report

Central venous catheters provide long-term available vascular access. They are useful for central venous pressure monitoring, rapid fluid management, massive transfusion and direct cardiovascular medication, especially in operation. Central venous catheterization is usually performed by the landmark bedside technique without imaging guidance. The complications of central venous catheterization ...

متن کامل

Upper extremity deep vein thrombosis after migration of peripherally inserted central catheter (PICC)

INTRODUCTION Peripherally inserted central venous catheters (PICC) are widely used in cancer patients and ultrasound-guided PICC insertion could improve success rate. The tip position of the catheter should be located at the border of lower one-third of the superior vena cava (SVC) and cavo-atrial junction. The migration is malposition at the late stage after PICCs were inserted, and catheter m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -