Characteristics of the NICMOS Detectors

نویسندگان

  • C. J. Skinner
  • L. E. Bergeron
  • D. Daou
چکیده

We present an overview of the properties of the NICMOS flight detectors as measured on-orbit, including the flat-field response, the dark current, the linearity, and the read-noise. We show for the first time all the dependencies of the various components of a NICMOS dark exposure, and show how to generate “synthetic” dark current calibration files. An unexpected time-varying bias known as the “pedestal”, is described, along with some efforts to remedy it. We describe the effects on the detectors of exposure to very bright sources, and finally, we briefly describe the sensitivity of NICMOS to cosmic rays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Photometric Performance of NICMOS

This contribution reviews our current understanding of NICMOS photometric characteristics paying special attention to the absolute calibration of NICMOS detectors and the sources of systematic uncertainty when performing the calibration. Preliminary results based on SMOV and Cycle 7 calibration programs are presented.

متن کامل

Highlights from Hst/nicmos

The Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope in February 1997. After twenty-two months of operation the 110 kg supply of solid N2, which cooled the NICMOS-3 HgCdTe detectors, was exhausted. The cryostat warmed up leaving the instrument in an electromechanically functional, but scientifically non-viable, passive state. Following a th...

متن کامل

A Test of non-Standard Gain Settings for the NICMOS Detectors

We report on the results of a test program to explore the potential scientific benefit of using non-standard gain settings in NICMOS observations. While this capability had originally been included in the NICMOS design, it has never been used on orbit. We present our analysis of the test data, discuss the potential scientific benefits, and outline the necessary modifications to planning, implem...

متن کامل

NICMOS Temperature Monitoring

The NICMOS detectors are sensitive to the operating temperature. During the Cycle 7 era, NICMOS was cooled through cryogenic solid nitrogen. This resulted in an operating temperature varying from 61K to 62.5K before the nitrogen was exhausted. Using the new NICMOS Cooling System (NCS), the nominal temperature is significantly more stable, but at a higher temperature, 77.15 K. The stability of t...

متن کامل

Update on NICMOS Reference Flies

The response of the three NICMOS detectors when observing a standard star showed variations of 2-4% during both the era before the installation of the NICMOS Cooling System, NCS (1997-98) and during the era of NCS operation 2002-08. If uncorrected, these variations could affect the quality of reduced NICMOS images, introducing errors in the photometry. Here we discuss steps taken to mitigate th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998