A shear gradient-activated microfluidic device for automated monitoring of whole blood haemostasis and platelet function
نویسندگان
چکیده
Accurate assessment of blood haemostasis is essential for the management of patients who use extracorporeal devices, receive anticoagulation therapy or experience coagulopathies. However, current monitoring devices do not measure effects of haemodynamic forces that contribute significantly to platelet function and thrombus formation. Here we describe a microfluidic device that mimics a network of stenosed arteriolar vessels, permitting evaluation of blood clotting within small sample volumes under pathophysiological flow. By applying a clotting time analysis based on a phenomenological mathematical model of thrombus formation, coagulation and platelet function can be accurately measured in vitro in patient blood samples. When the device is integrated into an extracorporeal circuit in pig endotoxemia or heparin therapy models, it produces real-time readouts of alterations in coagulation ex vivo that are more reliable than standard clotting assays. Thus, this disposable device may be useful for personalized diagnostics and for real-time surveillance of antithrombotic therapy in clinic.
منابع مشابه
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of...
متن کاملDuration of exposure to high fluid shear stress is critical in shear-induced platelet activation-aggregation.
Platelet functions are increasingly measured under flow conditions to account for blood hydrodynamic effects. Typically, these studies involve exposing platelets to high shear stress for periods significantly longer than would occur in vivo. In the current study, we demonstrate that the platelet response to high shear depends on the duration of shear exposure. In response to a 100 dyn/cm2 shear...
متن کاملA simple method for activating the platelets used in microfluidic platelet aggregation tests: Stirring-induced platelet activation
High-shear stimulation is well known as one of the key factors affecting platelet activation and aggregation, which can lead to the formation of a thrombus. In one of our previous studies, we introduced migration distance-based platelet function analysis in a microfluidic system. In this study, we set out to examine the effects of stirring on shear-induced platelet activation and aggregation in...
متن کاملMicrofluidic Networks for Studying Thrombosis
The flux of platelet agonists into flowing blood is a critical event in thrombosis and hemostasis. However, few in vitro methods exist for examining and controlling the role of platelet agonists on clot formation and stability under hemodynamic conditions. In this project, we fabricated a membrane-based method for introducing a solute into flowing blood at a defined flux [1]. The device consist...
متن کاملDisposable Bioanalytical Microdevice for Monitoring the Effect of Anti-platelet Drugs
We report a disposable self-powered integrated microfluidic chip that enables a rapid and simple plateletfunction assay from small samples of whole blood. The chip integrates a single-cell adhesion assay with a microfluidic platform; it enables accurate quantification of platelet adhesion, and it controls whole blood flow rate, shear stress, volume of sample, and assay time.
متن کامل