Application of the bootstrap to calibration experiments.
نویسندگان
چکیده
In calibration experiments, a number of samples of known concentration are used to establish the relationship between a measured response and sample concentration; this relationship is then used to estimate the unknown concentration of further samples from their measured responses. In addition to the estimates themselves, it is useful to have available some measure of their precision, usually given in the form of confidence limits. The standard method of inverting prediction limits is found to work well in simple situations, but in nonlinear multivariate calibration it becomes intractable. The bootstrap offers an alternative methodology, but in the calibration framework its application is not obvious. We describe some considerations in bootstrapping calibration data and compare our methods with a previous attempt and with the standard method in linear, nonlinear, and multivariate situations. The bootstrap is found to be a useful tool in those situations where the standard method is difficult to implement.
منابع مشابه
On Calibration and Application of Logit-Based Stochastic Traffic Assignment Models
There is a growing recognition that discrete choice models are capable of providing a more realistic picture of route choice behavior. In particular, influential factors other than travel time that are found to affect the choice of route trigger the application of random utility models in the route choice literature. This paper focuses on path-based, logit-type stochastic route choice models, i...
متن کاملBagging for robust non-linear multivariate calibration of spectroscopy
This paper presents the application of the bagging technique for non-linear regression models to obtain more accurate and robust calibration of spectroscopy. Bagging refers to the combination of multiple models obtained by bootstrap re-sampling with replacement into an ensemble model to reduce prediction errors. It is well suited to “non-robust” models, such as the non-linear calibration method...
متن کاملSpectrophotometric Determination of Corticosteroids and Its Application in Pharmaceutical Formulation
A simple, sensitive and economically viable spectrophotometric method for the determination of corticosteroids (predinsolone {PSL}, dexamethasone {DEX}, prednisone {PS}, betamethasone sodium phosphate {BEP} and hydrocortisone {HYD} has been developed. The method involves the oxidation of corticosteroids by iron (III) and subsequent complexation of iron (II) with potassium hexacynoferrate (III),...
متن کاملDevelopment and application of a new sensitive spectrophotometric-multivariate calibration method to the simultaneous determination of hydrazine and acetylhydrazine using silver nanoparticles
In this paper, multivariate calibration methods of partial least squares (PLS) and principle component regression (PCR) were investigated in simultaneously determination of hydrazine (HZ) and acetylhydrazine (AHZ). The aforementioned methods are based on formation of the silver nanoparticles (AgNPs) from the reaction of HZ and AHZ with Ag+ ions as oxidizing agent in the presence of citrate ions...
متن کاملUs Ska Tdp
We report on a broader evaluation of statistical bootstrap resampling methods as a tool for pixel-level calibration and imaging fidelity assessment in radio interferometry. Pixel-level imaging fidelity assessment is a challenging problem, important for the value it holds in robust scientific interpretation of interferometric images, enhancement of automated pipeline reduction systems needed to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 68 5 شماره
صفحات -
تاریخ انتشار 1996