A study on the changes in attractive force of magnetic attachments for overdenture.

نویسندگان

  • Han-Wool Leem
  • In-Ho Cho
  • Jong-Hyuk Lee
  • Yu-Sung Choi
چکیده

PURPOSE Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Denture Cleansing Solutions on Retention of Two Types of Overdenture Attachments

Background and Aim: There is lack of information regarding the effect of different denture cleansing solutions on the retention of attachments. This study aimed to as-sess the effect of denture cleansing solutions on the retention of Dalbo-Plus and Loca-tor attachment systems. Materials and Methods: This study evaluated 160 attachments including 80 Locator and 80 Dalbo-Plus attachment systems....

متن کامل

Magnet retained Overdenture : A case report

Recent advances in dentistry have enabled different treatment options in prosthetic dentistry, one of them is in relation to magnets which are available in small size and with strong attractive force. This magnets can be used for overdenture attachments which increases the stability of denture and reduces the lateral forces on abutment tooth. Rationale for tooth supported overdenture are to pre...

متن کامل

Evaluation of stable retentive properties of overdenture attachments.

OBJECTIVES To evaluate fatigue of stud (ERA Overdenture (orange and white), Locator Root (pink) and OP anchor # 4) and magnetic (Magfit EX600W) attachments by measuring maximum retentive force. To compare retentive force of overdenture attachments after their reach stable retention. To determine minimum number of cycles required to reach stable retention. MATERIAL AND METHODS Three specimens ...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of advanced prosthodontics

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2016