Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty

نویسندگان

  • Inari Kostensalo
  • Mika Junnila
  • Petri Virolainen
  • Ville Remes
  • Markus Matilainen
  • Tero Vahlberg
  • Pekka Pulkkinen
  • Antti Eskelinen
  • Keijo T Mäkelä
چکیده

BACKGROUND AND PURPOSE Previous population-based registry studies have shown that larger femoral head size is associated with reduced risk of revision for dislocation. However, the previous data have not included large numbers of hip resurfacing arthroplasties or large metal-on-metal (> 36-mm) femoral head arthroplasties. We evaluated the association between femoral component head size and the risk of revision for dislocation after THA by using Finnish Arthroplasty Register data. PATIENTS AND METHODS 42,379 patients who were operated during 1996-2010 fulfilled our criteria. 18 different cup/stem combinations were included. The head-size groups studied (numbers of cases) were 28 mm (23,800), 32 mm (4,815), 36 mm (3,320), and > 36 mm (10,444). Other risk factors studied were sex, age group (18-49 years, 50-59 years, 60-69 years, 70-79 years, and > 80 years), and time period of operation (1996-2000, 2001-2005, 2006-2010). RESULTS The adjusted risk ratio in the Cox model for a revision operation due to dislocation was 0.40 (95% CI: 0.26-0.62) for 32-mm head size, 0.41 (0.24-0.70) for 36-mm head size, and 0.09 (0.05-0.17) for > 36-mm head size compared to implants with a head size of 28 mm. INTERPRETATION Larger femoral heads clearly reduce the risk of dislocation. The difference in using heads of > 36 mm as opposed to 28-mm heads for the overall revision rate at 10 years follow-up is about 2%. Thus, although attractive from a mechanical point of view, based on recent less favorable clinical outcome data on these large heads, consisting mainly of metal-on-metal prostheses, one should be cautious using these implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of femoral head size and surgical approach on risk of revision for dislocation after total hip arthroplasty

Background and purpose - Recurrent dislocation is the commonest cause of early revision of a total hip arthropasty (THA). We examined the effect of femoral head size and surgical approach on revision rate for dislocation, and for other reasons, after total hip arthroplasty (THA). Patients and methods - We analyzed data on 166,231 primary THAs and 3,754 subsequent revision THAs performed between...

متن کامل

Measuring the Impact of Femoral Head Size on Dislocation Rates Following Total Hip Arthroplasty

PURPOSE The purpose of this study was to evaluate if the femoral head's size has an impact on dislocation rates following total hip arthroplasty (THA). MATERIALS AND METHODS Five hundreds forty-three THA performed using a posterolateral approach in our hospital and followed up more than 6 months were included in this study. We evaluated dislocation rates based on the size of femoral head (28 ...

متن کامل

The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis

BACKGROUND AND PURPOSE The effects of patient-related and technical factors on the risk of revision due to dislocation after primary total hip arthroplasty (THA) are only partly understood. We hypothesized that increasing the femoral head size can reduce this risk, that the lateral surgical approach is associated with a lower risk than the posterior and minimally invasive approaches, and that g...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial.

BACKGROUND The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 84  شماره 

صفحات  -

تاریخ انتشار 2013