Infrared Thermographic Assessment of Cooling Effectiveness in Selected Dental Implant Systems
نویسندگان
چکیده
The excessive temperature fluctuations during dental implant site preparation may affect the process of bone-implant osseointegration. In the presented studies, we aimed to assess the quality of cooling during the use of 3 different dental implant systems (BEGO®, NEO BIOTECH®, and BIOMET 3i®). The swine rib was chosen as a study model. The preparation of dental implant site was performed with the use of 3 different speeds of rotation (800, 1,200, and 1,500 rpm) and three types of cooling: with saline solution at room temperature, with saline solution cooled down to 3°C, and without cooling. A statistically significant difference in temperature fluctuations was observed between BEGO and NEO BIOTECH dental systems when cooling with saline solution at 3°C was used (22.3°C versus 21.8°C). In case of all three evaluated dental implant systems, the highest temperature fluctuations occurred when pilot drills were used for implant site preparation. The critical temperature, defined in the available literature, was exceeded only in case of pilot drills (of all 3 systems) used at rotation speed of 1,500 rpm without cooling.
منابع مشابه
Multiscale analysis of thermography imaging dynamic for sol-gel coating discrimination
Infrared thermography is a non-destructive method that is becoming attractive due to its ability to inspect noninvasively large areas in short times. This work demonstrates that the analysis of the thermographic response of coating layer can be greatly improved with a multiscale decomposition. Based on 2D discrete wavelets transform, effective scales in the thermographic responses of samples ca...
متن کاملThe Frequency of Dentists’ Use and Satisfaction of Different Dental Implant Systems in Qom City, (Iran)
Abstract Background and Objectives: Considering the increasing use of implant, many dentists are willing to use implants with the highest quality and ease of work. Therefore, the present study was performed to investigate the frequency of use and satisfaction of the dentists from different dental implant systems in Qom city. Methods: In this descriptive and cross-sectional study, a questionn...
متن کاملTiming of the thermographic assessment of burns.
The thermographic assessment of burns using infrared imaging has previously been shown to be a useful aid in the estimation of burn depth. In this study, thermographic images of burns, obtained from 65 patients over a 4-year period, were reviewed. An infrared transparent, water-impermeable membrane was used as a wound cover to abolish evaporative cooling artefacts. Single images were obtained f...
متن کاملThe accuracy of various torque wrenches used in dental implant systems
Introduction: The purpose of this study was to compare the accuracy of the torque wrenches used in different dental implant systems. Methods: We evaluated 42 torque wrenches used in different dental clinics in Mashhad, Iran, using a digital torque meter (Mark 10). High (25, 30 and 35 N·cm) and low (15 N·cm) levels of torque were examined. Ten tests were performed on each wrench, and the mean va...
متن کاملUse of infrared thermography as an endpoint in therapeutic trials of Raynaud's phenomenon and systemic sclerosis.
OBJECTIVES To perform a systematic review evaluating the use of infrared thermography (IRT) as an endpoint in clinical trials of Raynaud's phenomenon (RP). METHODS Articles reporting the use of IRT and Raynaud's phenomenon were identified following systematic searches of PubMed, EMBase, MEDLINE and AMED databases. Articles incorporating IRT as an endpoint in a therapeutic trial were selected ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016