Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.
نویسندگان
چکیده
PURPOSE To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference between the combined thickness of the central cornea and tear film and the true corneal thickness obtained after instillation of artificial tears. Dynamic tear distribution was determined by OCT imaging immediately and 5, 20, 40, and 60 minutes after tear instillation. Measurements taken after two blinks of one eye at each visit were repeated on the next day. Measurements from the companion eye were made on separate days. RESULTS There were no significant differences between the two measurements of each variable made on consecutive days. At baseline, upper tear meniscus variables were strongly correlated with the comparable lower meniscus variables. However, there were no significant correlations between TFT and any tear meniscus variable. Immediately after instillation of artificial tears, all measured variables increased significantly. TFT, upper and lower menisci heights, and upper meniscus area remained elevated for at least 5 minutes. In addition there were significant correlations between TFT and the lower tear meniscus height and area. CONCLUSIONS The custom-built OCT showed good repeatability and holds promise in measuring the dynamic distribution of artificial tears on the ocular surface.
منابع مشابه
Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.
Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before ins...
متن کاملCorneal sensitivity after topical bromfenac sodium eye-drop instillation
PURPOSE To evaluate the safety of bromfenac sodium eye drops from the standpoint of corneal sensitivity and tear secretion in healthy controls following instillation for 1 month. METHODS A prospective single-blind parallel clinical study was conducted in 20 eyes of ten healthy volunteers with no history of ocular or systemic allergic disease, dry eye, contact lens wear, or ocular surgery. Par...
متن کاملComparative In vitro Cytotoxicity of Artificial Tears
Dry eye is one of the most common ocular conditions in the world with prevalence of over 10 million in the United States alone [1]. It can result in severe ocular symptoms and visual disability. The primary treatment for dry eyes is instillation of artificial tears over the course of the day [2]. The role of artificial tears is to either replace or augment the native tear film, with the goal of...
متن کاملMucoadhesive properties of chitosan-coated ophthalmic lipid emulsion containing indomethacin in tear fluid.
To evaluate the residence of chitosan-coated emulsion (CE) containing indomethacin in tears, the drug retention of CE in tear fluid was compared with non-coated emulsion (NE) after instillation in rabbit eyes. CE had mean concentrations 3.6-fold and 3.8-fold higher than NE at 0.5 h and 0.75 h after instillation, respectively. Mean residence time and half-life of CE were lengthened to 1.5-fold a...
متن کاملNovel formulation of glycerin 1% artificial tears extends tear film break-up time compared with Systane lubricant eye drops.
PURPOSE To evaluate the effectiveness of glycerin 1% formulated with the novel and proprietary ophthalmic excipient poly(l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) (Eyeon Particle Sciences LLC) in extending tear film break-up time (TFBUT) compared with a market-leading artificial tear formulation of propylene glycol (0.3%) and polyethylene glycol (0.4%) (Systane(®) Lubricant Eye Drops; A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 8 شماره
صفحات -
تاریخ انتشار 2006