Electrical alternans and cardiac electrical instability.

نویسندگان

  • J M Smith
  • E A Clancy
  • C R Valeri
  • J N Ruskin
  • R J Cohen
چکیده

We investigated the relationship between electrical alternans and cardiac electrical stability in a series of 20 dog experiments and in a pilot clinical study. Electrical alternans was detected in both the QRS complex and the ST-T wave by use of a novel multidimensional spectral technique. The magnitude of the alteration was expressed as the alternating electrocardiographic morphology index (AEMI), expressed as parts per million of waveform energy. Electrical stability in the dog preparations was assessed via the ventricular fibrillation threshold measurement, and in the clinical studies via programmed stimulation. In 10 dog experiments, systemic hypothermia resulted in a 60% decrease in ventricular fibrillation threshold (VFT) (p less than .0001) and a significant increase in both AEMI(QRS) form 3.7 +/- 3.0 to 1448 +/- 548 (p less than .0001) and AEMI(ST-T) from 43.9 +/- 18.4 to 19,178 +/- 5579 (p less than .0001). In 10 dog experiments, transient coronary artery ligation also resulted in a 60% decrease in VFT (p less than .0001), an increase from 76.3 +/- 46.5 to 245 +/- 11 in AEMI(QRS) (p less than .05), and an increase from 842 +/- 505 to 1365 +/- 392 in AEMI(ST-T) (p less than .002). In 119 observations in 20 animal experiments, the rank correlation between VFT and AEMI(QRS) was -.30 (p less than .001), with that between VFT and AEMI(ST-T) being -.55 (p less than .0001). In a double-blind pilot clinical trial consisting of 23 studies in 19 patients, the result of electrophysiologic testing was used as an independent measure of cardiac electrical stability. Alternation in waveform morphology identified the inducible patient population with a sensitivity of 92%, a positive predictivity of 70%, and a specificity of 50% (p less than .05). We conclude that analysis of subtle beat-to-beat variability in electrocardiographic morphology may provide a noninvasive measure of cardiac electrical stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical alternans in cardiac tamponade.

Of nine patients with pericardial effusion due to various causes, four developed cardiac tamponade. Electrical alternans was present in all four, being total in three and ventricular in one. The alternans corresponded very well with the clinical diagnosis of cardiac tamponade and the radiological signs of a large pericardial effusion. In two patients alternans was present even with heart rates ...

متن کامل

Instability and spatiotemporal dynamics of alternans in paced cardiac tissue.

We derive an equation that governs the spatiotemporal dynamics of small amplitude alternans in paced cardiac tissue. We show that a pattern-forming linear instability leads to the spontaneous formation of stationary or traveling waves whose nodes divide the tissue into regions with opposite phase of oscillation of action potential duration. This instability is important because it creates dynam...

متن کامل

Alternans goes subcellular: a "disease" of the ryanodine receptor?

In 1872 Traube 1 first described pulsus alternans, a regular beat-to-beat alternation of the strength of the heartbeat. Since then, cardiologists and physiologists have learned that cardiac alternans can come in many flavors: as mechanical, electrical, or [Ca ]i transient alternans (Ca alternans).2 They also had to realize that alternans is a life-threatening condition, less so because of impai...

متن کامل

Electrical Instability Due to Regional Increase in Extracellular Potassium Ion Concentration.

INTRODUCTION Ventricular tachycardia and ventricular fibrillation are the two most dangerous arrhythmias. Both are related to reentrant electrical activity in the ventricles. Many studies of arrhythmias consider a homogeneous sheet of cardiac tissue. Since normal ventricular myocardium is inhomogeneous and inhomogeneities play an important role in the induction of reentry, we investigate the ef...

متن کامل

DIAGNOSTIC METHODS VENTRICULARA Electrical alternans and cardiac electrical instability

We investigated the relationship between electrical alternans and cardiac electrical stability in a series of 20 dog experiments and in a pilot clinical study. Electrical alternans was detected in both the QRS complex and the ST-T wave by use of a novel multidimensional spectral technique. The magnitude of the alternation was expressed as the alternating electrocardiographic morphology index (A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 77 1  شماره 

صفحات  -

تاریخ انتشار 1988